摘要
6502电气集中联锁中6‰坡道延续电路为非定型电路,在特定情况下可能存在一定安全隐患,电路经过修改,将能消除上述隐患。
In 6502 electric interlocking system,the circuit of successive route with gradient 6‰ is nonfinalize one.So,there are some hidden troubles at some special station.The troubles could be solved by modifying the circuit.
出处
《铁道通信信号》
2013年第1期56-57,共2页
Railway Signalling & Communication
关键词
6502电气联锁
6‰坡道延续进路
电路修改
6502 electric interlocking
Successive route with 6‰ gradient