期刊文献+

金属塑性应变比r值测定方法误差分析 被引量:10

ERROR ANALYSIS ON THE DETERMINATION METHOD FOR THE PLASTIC STRAIN RATIO r VALUE OF METALLIC MATERIALS
下载PDF
导出
摘要 通常使用手工、半自动和全自动三种方法测定金属塑性应变比 r值。对这三种测定方法的测定误差进行了分析 ,不同测定方法其总测量不确定度不同 ,取决于相关的计量参数的测量误差、r值和测定 r值的应变水平 ,就目前现行国际标准 (ISO 1 0 1 1 3∶ 1 991 )所规定的试验方法要求而言 。 Three methods, i.e. manual, semi auto and full auto methods, were usually used to determine the plastic strain ratio of metallic materials — r value. Error analysis on the three methods was made. The total measurement uncertainties with defferent determining method were not identical and they depended on the measuring errors of the relavent metrical parameters, the r value and the strain level at which the r value was measured. For the testing method requirements specified by the current international standard ISO 10113∶1991, the accuracy of the manual method was higher than those of the semi auto and full auto methods.
作者 梁新邦
机构地区 钢铁研究总院
出处 《理化检验(物理分册)》 CAS 2000年第5期209-212,共4页 Physical Testing and Chemical Analysis(Part A:Physical Testing)
关键词 金属材料 塑性应变比 误差分析 r值 Metallic materials Mechanical testing Plastic strain ratio Error analysis
  • 相关文献

同被引文献47

引证文献10

二级引证文献25

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部