摘要 The two-dimensional interpolating readout, a new readout concept based on resistive anode structure, was studied for the micro-pattern gaseous detector. Within its high spatial resolution, the interpolating resistive readout structure leads to an enormous reduction of electronic channels compared with pure pixel devices, and also makes the detector more reliable and robust, which is attributed to its resistive anode relieving discharge. A GEM (gaseous electron multiplier) detector with 2D interpolating resistive readout structure was set up and the performance of the detector was studied with ^55Fe 5.9 keV X-ray. The detector worked stably at the gain up to 3.5 × 104 without any discharge. An energy resolution of about 19%, and a spatial resolution of about 219 μm (FWHM) were reached, and good imaging performance was also obtained. The two-dimensional interpolating readout, a new readout concept based on resistive anode structure, was studied for the micro-pattern gaseous detector. Within its high spatial resolution, the interpolating resistive readout structure leads to an enormous reduction of electronic channels compared with pure pixel devices, and also makes the detector more reliable and robust, which is attributed to its resistive anode relieving discharge. A GEM (gaseous electron multiplier) detector with 2D interpolating resistive readout structure was set up and the performance of the detector was studied with ^55Fe 5.9 keV X-ray. The detector worked stably at the gain up to 3.5 × 104 without any discharge. An energy resolution of about 19%, and a spatial resolution of about 219 μm (FWHM) were reached, and good imaging performance was also obtained.
出处 《Chinese Physics C》 SCIE CAS CSCD 2013年第2期44-48,共5页 中国物理C(英文版)
关键词 interpolating readout resistive anode readout structure micro-pattern gaseous detector GEM interpolating readout, resistive anode readout structure, micro-pattern gaseous detector, GEM
  • 相关文献

参考文献8

  • 1Chechik R,Breskin A,Shalem C et al. Nucl. Instrum.Methods A . 2004
  • 2LüXin-Yu,FAN Rui-Rui,CHEN Yuan-Bo et al. CPC (HEP&NP) . 2012
  • 3Sarvestani A,Besch H J,Junk M et al. Nuclear Instruments and Methods . 1998
  • 4Orthen A,Wagner H,Besch H J et al. Nuclear Instruments and Methods . 2002
  • 5Wagner H,Besch H J,Menk R H et al. Nuclear Instruments and Methods . 2002
  • 6Sauli F. Nuclear Instruments and Methods . 1997
  • 7Giomataris Y,Rebourgeard Ph,Robert J P et al. Nucl In- strum. Methods A . 1996
  • 8Besch H J,Junk M,Meiβner W et al. Nuclear Instruments and Methods . 1997