摘要 天脊煤化工集团有限责任公司引进的与硝酸装置配套的废热锅炉因过热、蒸发器受热面严重腐蚀变形 ,影响正常生产。该文介绍了对废热锅炉过热器、蒸发器的修复改造经验。图 1表 The superheater, and evaporator's heating surface of a waste heat boiler, which is matching a nitric acid installation and was imported by the Tianji Coal Chemical Group Ltd., incurred serious corrosion and deformation impairing normal operation. The paper reports on experiences gained in restoring and renorating the superheater and the evaporator of the waste heat boiler. Fig 1 and tables 6
出处 《发电设备》 2000年第3期16-18,共3页 Power Equipment
关键词 废热锅炉 过热器 蒸发器 硝酸装置 waste heat boiler seperheater evaporator renovation