摘要 微细颗粒物尤其是PM2.5对人和自然环境的危害日益严重,受到社会的广泛关注。常规静电除尘器对PM2.5粒子的去除效果不理想,双极微粒聚合器可有效减少此类粉尘的排放。通过模拟实际工况条件,建立试验平台,对该聚合器进行了大量试验研究。结果表明:双极电晕荷电能使粉尘聚合效果明显增大,聚合器投运后PM2.5质量浓度下降15.9%,数量浓度下降20.8%,实现了电除尘器的提效和减排。 Fine particles especially the hazards of PM2.5 on human and natural environment is increasingly seri- ous ,which is widely concerned all over the world. While the collection efficiency of conventional electrostatic pre- cipitator on PM.2.5 is not ideal,the bipolar - charged fluid mixing agglomerator can reduce the emission of PM2.5 effectively. By simulating the actual working conditions and establish the test platform,a number of experimental study on this aggregator has carried out. Experimental results were obtained as follow:Bipolar corona charge can significantly increased dust aggregation effect;when the agglomerator put into operation,the mass concen- tration of PM:~ decreased by 15.9% ,the number concentration decreased by 20.8%. The results show that the agglomerator has realized high efficiency and low emission of electrostatic precipitator.
出处 《电力科技与环保》 2013年第1期22-23,共2页 Electric Power Technology and Environmental Protection
关键词 聚合器 PM2 5 双极荷电 静电除尘器 agglomerator PM2.5 bipolar - charged electrostatic precipitator
  • 相关文献

参考文献3

二级参考文献10

  • 1[1]Y. Koizumi et al. Bipolar-charged submicron particle agglomeration.Journal of Electrostatics 1995.35:55 ~ 60.
  • 2[2]S. Kanazawa et al. Submicron particle agglomeration and precipitation by using a bipolar charging method. Journal of Electrostatics 1992. 93:193 ~ 209.
  • 3[3]Y. Koizumi et al, Estimation of the agglomeration coefficient of bipolar-charged aerosol particles. Journal of Electrostatics 2000.48:93 ~ 101.
  • 4[4]Tsuneo Watanabe et al. Review of particle agglomeration. J. Aerosol Sci.1995.26(1) :19 ~ 20.
  • 5[5]S. Masuda et al. Sensing of back discharge and bipolar ionic current.Journal of Electrostatics. 1981.10:73 ~ 80.
  • 6[6]A. Laitinen et al. Bipolar charged aerosol agglomeration with altering electric fiied in laminar gas flow. Journal of Electrostatics 1996. 38:303~ 315.
  • 7[7]Srinivas Vemury et al. Coagulation of symmetric and asymmetric bipolar aerosols. J. Aerosol Sci. 1997.28: 599 ~ 611.
  • 8Chan C K,Xiaohong Yao. Air pollution in mega cities in China[ J]. Atmospheric Environment,2008, (42) :31 - 42.
  • 9Honghong Yi. Fine particle and trace element emissions from an an- thracite coal - fired power plant equipped with a bag - house in China [ J ]. Fuel,2008, ( 87 ) : 2 050 - 2 057.
  • 10王连泽,贺美陆,孟亚力.双极荷电粉尘颗粒凝聚的初步研究[J].环境工程,2002,20(3):10-10. 被引量:29

共引文献32

同被引文献25

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部