期刊文献+

伍迪BM2.7型电解槽紧急跳闸停车的分析 被引量:1

Analysis on emergency trip and shutdown of Uhdenora BM2.7 electrolyzers
下载PDF
导出
摘要 介绍了2套离子膜电解槽并网运行工艺和一次电解槽紧急跳闸停车的经过。分析了紧急跳闸停车的原因。提出了须加强对控制点的巡检以减少停车次数,而且要从多专业的角度来正确分析紧急跳闸停车的表象、原因,才能更好地指导生产,防止频繁开停车。 The parallel operation process of two sets of ion-exchange membrane electrolyzers and the course of an emergency trip and shutdown of electrolyzers are introduced. The causes of the emergency trip and shutdown are analyzed. Routine inspection should be strengthened in order to reduce shutdowns. Moreover, the appearances and causes of emergency shutdowns should be analyzed correctly from many professional perspectives and thus production is directed well and frequent startup and shutdown are avoided.
作者 孙俊鑫
机构地区 云南省化工学校
出处 《氯碱工业》 CAS 2013年第1期19-21,共3页 Chlor-Alkali Industry
关键词 电解槽 离子膜法 跳闸 停车 electrolyzer ion-exchange membrane process trip shutdown
  • 相关文献

参考文献3

  • 1聂日丛,康献春.伍迪与北化机离子膜电解槽的并网[J].氯碱工业,2009,45(9):20-21. 被引量:5
  • 2蒋守军.日本旭化成离子膜电解槽运行的电气特性[A]葫芦岛:《氯碱工业》编辑部,200934-37.
  • 3邢家悟;刘东升.离子膜法制烧碱操作问答[M]北京:化学工业出版社,2009.