期刊文献+

辐射电磁骚扰测量中归一化偏差分析

Analysis on the Deviation of Normalized Radiated Disturbance Measurement Results
下载PDF
导出
摘要 用3米法和10米法半电波暗室测量辐射电磁骚扰时,在180~260 MHz频段上应用20 dB/10倍的反比因子归一化测量结果存在一定的偏差。3米法半电波暗室归一化后的结果偏小,导致最终被测试设备在3米法半电波暗室测量会比在10米法半电波暗室测量时,更容易满足辐射电磁骚扰的限值要求。分析了归一化偏差产生的原因,并提出了加入辅助的修正系数修正测试结果的方法。 By using the method of inverse proportionality factor of 20 dB per decade, the measurement results of radiated disturbance from 3 m test could be normalized to reconstruct data as measured by 10 m test method. However, this method could produce devia- tion in the frequency range of 180~260 MHz. Finally, the reason of deviation is analyzed, and the correction method is put forward.
作者 唐承军
出处 《安全与电磁兼容》 2012年第6期57-59,共3页 Safety & EMC
关键词 偏差 辐射骚扰 反比因子 归一化 半电波暗室 CISPR22 deviation radiated disturbance inverse proportionality factor normalize semi-anechoic chamber CISPR 22
  • 相关文献

参考文献5

  • 1CISPR Subcommittee I. Information technology equipment-Radio disturbance characteristics-Limits and methods of measurement[S].2006.
  • 2全国无线电干扰标准化技术委员会Ⅰ分会.信息技术设备的无线电骚扰限值和测量方法[S]北京:中国标准出版社,2008.
  • 3Sanjaya Maniktala.EMI溯源:从麦克斯韦到CISPR[J]电子工程专辑,200411.
  • 4汤世贤.微波测量[M]北京:国防工业出版社,1983.
  • 5叶德培.量不确定度[M]北京:国防工业出版社,1996.