摘要 建立测定铁质叶酸片中铁含量的方法。用1∶1的盐酸溶液和10%的盐酸羟胺处理样品,使样品中的铁全部转化成Fe2+,Fe2+与0.15%的邻菲罗啉显色剂络合生成稳定的橙红色化合物,按分光光度法,在511nm处测定吸光度。结果表明,铁离子浓度在0.022 4~0.112 0mg/mL范围内呈现良好线性。平均回收率为99.2%。RSD为1%(n=6)。该方法操作简单,样品前处理简便,结果稳定、精确,适用范围广,可用于铁质叶酸片中铁元素含量的测定。 A method for the determination of iron content in health food tablets by ultraviolet spectrophotometry was established. Use 50- of the hydrochloric acid solution and 10G of hydroxylamine hydrochloride processing samples to make all the iron in samples change into Fe^2+. Fe^2+ can react with 0.15% of the phenanthroline solution to form a stable orange red compound. Then all the iron can be deteminated by spectrophotometrie method on 511 nm. Results: Fe^2+ was good linear over the range 0. 022 4-0. 112 0 mg/mL, the average recovery of Fe^2+ was 99. 2%,and RSD was 1% (n = 6). This method is simple, stable, precise and accurate. So this study can be used in determination of iron content, in iron folic acid tablets.
作者 秦瑜丽
出处 《食品与机械》 CSCD 北大核心 2013年第1期99-101,共3页 Food and Machinery
关键词 分光光度法 含量测定 片剂 spectrophotometric method iron determination tablets