摘要
将脱硫废水引入渣溢水系统进行综合处理,使脱硫废水排放得到合理解决。为此,针对脱硫废水对设备的氯离子腐蚀问题提出了合理的处理方案,各项指标符合废水回用或排放标准,表明脱硫废水引入渣溢水系统处理是完全可行的,并实现湿排渣系统零溢流。
To introduce desulfurization waste water in dust overflow water system for overall processing may reasonably solve desulfurization waster water discharge problem. Therefore, this paper proposes reasonable processing scheme on the basis of chloriditon corrosion to the equipment by desulfurization waste water. The practical application shows that each index con- forms to waste water recovery or discharge standards and the practice of introducing desulfurization waste water in dust over- flow water system for processing is feasible which may realize zero overflow of wet dust remove system.
出处
《广东电力》
2013年第1期110-113,共4页
Guangdong Electric Power
关键词
脱硫废水
湿排渣系统
氯离子腐蚀
零溢流
desulfurization waste water
.wet dust remove system
chloridion corrosion
zero overflow