期刊文献+

浸没式方型超滤膜装置处理沉后水的中试研究 被引量:1

Pilot research on treatment of settled water by submerged square ultrafiltration membrane
下载PDF
导出
摘要 以沉后水为原水,研究了方型超滤膜装置的影响因素和处理效果。结果表明,跨膜压差和温度均对膜通量产生影响;随着累计过滤水量的增加,跨膜压差增大;超滤膜组件对浊度的去除效果很好,出水浊度在0.007~0.12 NTU,且不受原水水质的影响;超滤膜组件对有机物的去除效果较差,CODMn去除率不足14%。 The Influencing factors and treatment effect of square uhrafihration membrane were researched taking the settled water as raw water. The results showed that transmembrane pressure (TMP) and temperature had influence on the membrane flux. TMP increased along with the increase of cumulative throughflow. Uhrafiltration membrane module had good effect on turbidity removal, the outflow turbidity was 0. 007 to 0.12 NTU, and raw water quality had no influence on it. However it had poor effect on organics removal, the removal rates of CODMn were less than 14%.
出处 《供水技术》 2013年第1期14-17,共4页 Water Technology
基金 国家水体污染控制与治理科技重大专项(2008ZX07421-002 2008ZX07422-005) 国家"十一五"科技支撑计划项目(2006BAJ08B06) 北京市自然科学基金资助项目(8092005)
关键词 沉后水 浸没式超滤膜 膜通量 浊度 有机物 settled water submerged ultrafiltration membrane membrane flux turbidity organics
  • 相关文献

参考文献4

二级参考文献18

  • 1李圭白,杨艳玲.超滤——第三代城市饮用水净化工艺的核心技术[J].供水技术,2007,1(1):1-3. 被引量:125
  • 2Laine J M,Vial D,Moulart P.Status after 10 years of operation-overview of UF technology today[J].Desalination,2000,131(1-3):17-25.
  • 3Madaeni S S.The application of membrane technology for water disinfection[J].Water Res,1999,33(2):301-308.
  • 4GELDER V, CHOWDHURY A M, LAWLER Z K. Conscientious particle counting[J]. J AWWA, 1999, 91(12) : 64-76.
  • 5GREGORY J. Turbidity fluctuations in flowing suspensions[J]. J Colloid Int Sci, 1985, 105: 357-371.
  • 6GREGORY J, NELSON D W. A new optical method for flocculation monitoring in solid-liquid separation[M]. Chichester: Ellis Horwood, 1984: 172-182.
  • 7夏盛骥.超滤膜净化地表水研究[D].哈尔滨:哈尔滨工业大学市政环境工程学院,2005.
  • 8CHANG J S, TSAI L J, VIGNESWARAN S. Experimental investigation of the effect of particle size distribution of suspend- ed particles on microfiltration[J]. Water Science and Technology, 1996, 34(9) : 133-144.
  • 9JACANGELO J G, ADHAM S A, LAINE J M. Mechamism of cryptosporidium, giadia and MS2 virus removal by mfand UF[J]. J AWWA, 1995, 88(9): 107-121.
  • 10LIPP P, BALDAUF G, SCHICK R, et al. Integration of ultrafiltration to conventional drinking water treatment for a better particle removal-efficiency and costs? [J]. Desalination, 1998, 119: 133-142.