宽排CT探测器CT剂量指数应用初探 被引量:2

Discussion on CT dose index for wide beam CT scanner
下载PDF
导出
摘要 目的:随着射线宽度的不断增加,传统CT剂量指数(CTDI)在表征CT剂量时遇到瓶颈问题,不能够很好地表征宽排CT探测器的剂量水平。本文探讨CTDI在CT宽排探测器剂量表征量方面的概念演化和应用方式。方法:介绍传统CTDI表征CT剂量的原理和方式,展示传统CTDI在表征宽排CT探测器时的局限性,阐述宽排CT探测器CTDI剂量表征量方式的演变过程,初步探讨宽排CT探测器CTDI表征和测量。结果:IEC在对传统CTDI进行修正的基础上推出分层次CTDI表征的方式,能更好适应宽排CT探测器的剂量表征。通过多点分次测量,新定义的分层次CTDI仍然可采用传统的150mm有机玻璃CT剂量体模和100mm电离室进行测量。结论:分层次CTDI表征方式能在保留传统CTDI基本概念和常规测试条件的基础上较好地表征宽排CT探测器的剂量水平。 Objective: With the increasing of beam width of CT scanner, traditional CT dose index(CTDI) encountered difficulties when expressing dosimetry for wide beam CT scanner. This article discussed the evolution and application of CTDI for wide beam CT scanners. Method: This article demonstrated principles of traditional CTDI and the limitation of it as a dosimetry for wide beam CT scanners, and introduced the evolution of CTDI for wide beam CT scanners and their principles and measurements. Results: IEC amended traditional CTDI and recommended a tiered approach to the definition of CTDI to be more adaptive for wide beam CT scanners. And with the approach of several time measurements at different locations, 150ram long PMMA phantom and 100mm long ion chamber could still be used for the measurements of new tiered CTDI. Conclusion: New tiered CTDI provided a more accurate dosimetry for wide beam CT scanners with a reservation of basic concept and measurement conditions of traditional CTDI.
作者 刘彬 白玫
出处 《中国医学装备》 2013年第2期1-4,共4页 China Medical Equipment
基金 国家自然科学基金(30870751)"多排螺旋CT临床成像质量与受检者受照剂量优化配比及评价方法研究"
关键词 体层摄影术 X线计算机 CT剂量指数 探测器 Tomography, X-ray computed CT dose index Detector
  • 相关文献

参考文献14

  • 1Shope TB,Gagne RM,Johnson GC. A method for describing the doses delivered by transmission x-ray computed tomography[J].Medical Physics,1981,(04):488-495.
  • 2Cohnen M,Poll LJ,Puettmann C. Effective doses in standard protocols for multi-slice CT scanning[J].European Journal of Radiology,2003,(05):1148-1153.
  • 3Hausleiter J,Meyer T,Hadamitzky M. Radiation dose estimates from cardiac multislice computed tomography in daily practice:impact of different scanning protocols on effective dose estimates[J].Circulation,2006,(10):1305-1310.
  • 4Hohl C,Mühlenbruch G,Wildberger JE. Estimation of radiation exposure in low-dose multislice computed tomography of the heart and comparison with a calculation program[J].European Journal of Radiology,2006,(08):1841-1846.
  • 5Perisinakis K,Damilakis J,Tzedakis A. Determination of the weighted CT dose index in modern multi-detector CT scanners[J].Physics in Medicine and Biology,2007,(21):6485-6495.
  • 6Geleijns J,Salvad ó Artells M,de Bruin PW. Computed tomography dose assessment for a160 mm wide,320 detector row,cone beam CT scanner[J].Physics in Medicine and Biology,2009,(10):3141-3159.
  • 7Dixon RL. A new look at CT dose measurement:beyond CTDI[J].Medical Physics,2003,(06):1272-1280.
  • 8Perisinakis K,Raissaki M,Theocharopoulos N. Reduction of eye lens radiation dose by orbital bismuth shielding in pediatric patients undergoing CT of the head:a Monte Carlo study[J].Medical Physics,2005,(04):1024-1030.
  • 9Ruan C,Yukihara EG,Clouse WJ. Determination of multislice computed tomography dose index(CTDI)using optically stimulated luminescence technology[J].Medical Physics,2010,(07):3560-3568.
  • 10Li X,Zhang D,Liu B. A practical approach to estimate the weighted CT dose index over an infinite integration length[J].Physics in Medicine and Biology,2011,(18):5789-5803.

同被引文献15

  • 1王晓峰,彭明辰.关于多排螺旋CT剂量的探讨[J].医疗设备信息,2004,19(12):23-25. 被引量:20
  • 2杨珂,吴建,李福生,陈英民.CT剂量指数(CTDI)的使用[J].中国辐射卫生,2005,14(1):76-77. 被引量:5
  • 3郑钧正.加强医疗照射防护的重点工作[J].中华放射医学与防护杂志,2005,25(2):105-106. 被引量:44
  • 4郭洪涛,刘勇,袁淑华.CT剂量指数(CTDI)测量研究[J].中国测试技术,2007,33(4):33-36. 被引量:33
  • 5McCollough CH.It is time to retire the computed tomography dose index(CTDI)for CT quality assurance and dose optimization[J].Med Phys, 2006,33(5): 1190-1191.
  • 6Perisinakis K,Damilakis J,Tzedakis A,et al. Determination of the weighted CT dose index in modern multi-detector CT scanners[J].Phys Med Biol, 2007,52(21) :6485-6495.
  • 7Boone JM.The trouble with CTDIoo[J].Med Phys, 2007,34(4): 1364-1371.
  • 8Shope TB,Gagne RM,Johnson GC.A method for describing the doses delivered by transmission x-ray computed tomography[J].Med Phys, 1981,8(4): 488-495.
  • 9Ruan C, Yukihara EG, Clouse WJ,et al. Deter- mination of multislice computed tomography dose index(CTDI)using optically stimulated luminescence technoloay[J]. Ivied Phys, 2010,37(7): 3560-3568.
  • 10Li X,Zhang D,Liu B. Caloalations of two new dose metrics proposed by AAPM Task Group 111 using the measurements with standard CT dosimetry phantoms[J]. Med Phys, 2013,40(8): 081914.

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部