摘要 随着科学技术的进步,医疗领域中各种类型的诊断设备不断地向高科技方向发展。尤其是CT设备已成为各级医院的常规诊断设备,对医院临床诊断有不可替代的作用,通过对GE Brivo CT 325型螺旋CT机故障进行分析,并针对不同类型的故障现象选择出其最优维修策略,可以快速地分析、判断和排除设备的故障,保养好机器。 With the advancing of science and technology, diagnostic equipments are led a trend for hi-tech development in today's medical field. People are increasingly aware of their importance, especially because they are becoming routine systems in hospitals, such as CT machines, which play a irreplacable role in clinic diagnosis there. The author of this article makes an analysis on the common failures of a spiral GE Brivo CT 325 and offers corresponding measures in how to dispel the defects quickly. The author finds that by analyzing failures, errors can be spot in a very short period of time and the machine can achieve better maintenance.
作者 张盛开
出处 《中国医学装备》 2013年第2期82-83,共2页 China Medical Equipment
关键词 螺旋CT机 故障诊断 典型 Spiral CT machine Failure diagnosis Foretype
  • 相关文献

参考文献5

二级参考文献7

  • 1姜蔚国,赵弘,佟丹,汪一.螺旋CT的原理及应用[J].中华放射学杂志,1995,29(1):60-61. 被引量:10
  • 2总后勤部卫生部.X线计算机断层扫描装置应用质量检测与评审规范(试行)[M].,-..
  • 3王云飞 姚春慧.延长CT机X线管寿命的经验点滴[J].中外医用放射技术杂志,1998,(3):42-43.
  • 4柳宝滨 李庆刚.浅谈如何延长CT球管使用寿命[J].中外医用放射技术杂志,1998,(8):34-34.
  • 5苏勤 马彪 等.飞利浦350型CT机二例故障的应急处理[J].中华放射学杂志,1999,(12):837-837.
  • 6王鸣鹏.实用CT检查技术学[M].北京:科学技术文献出版社,2000..
  • 7谢彦峰,邱海勇.延长Picker专家型CT球管使用寿命的探讨[J].实用放射学杂志,2001,17(5):374-374. 被引量:1