基于红外热像的微波养护车加热墙通风设计 被引量:3

Ventilation Design of Heating Wall of Microwave Maintenance Vehicle Based on Infrared Thermal Image
下载PDF
导出
摘要 针对微波养护车加热墙磁控管阵列的散热问题,提出了加热墙磁控管阵列的强制风冷策略基于红外热像仪采集的热图像,应用红外热像分析方法,解决了用于保护磁控管的温控开关的最优安装位置问题和加热墙内的通风道设计问题。新产品试制表明。 Aiming at the cooling problem of heating wall of the microwave maintenance vehicle, a forced air-cooling strategy of magnetron array was presented. Based on the infrared thermal images and analysis, a fit loca- tion to fix temperature control switch providing thermal protection for magnetron was found, and a ventilation duct design of the heating walt was demonstrated. Trial production proves that the forced air-cooling strategy is an effective and economical method to cool the magnetron array.
出处 《筑路机械与施工机械化》 2012年第10期68-71,共4页 Road Machinery & Construction Mechanization
基金 江苏省科技成果转化基金(BA2006068)
关键词 强制风冷 温控开关 红外热像 磁控管 forced air-cooling temperature control switch infrared thermal image magnetron