期刊文献+

TR组件发射波形畸变批次故障分析 被引量:1

Batch Fault Analysis of the Transmitting Waveform Distortion of T/R Module
下载PDF
导出
摘要 在某批次收发组件(TR组件)随整机系统测试时,出现发射波形畸变故障现象。通过对该故障的分析,暴露出TR组件测试系统衰减器与整机测试系统的衰减器类型和衰减量不同,造成测试结果不一致;TR组件的相关检验文件只按技术协议要求施加标准激励,无静态测试,从而造成小信号输入产生自激的批次故障;TR组件所用功放在脉冲供电方式下防过冲措施不到位等3方面问题。 The transmitting waveform distortion was happened during a system test of a batch of T/R module. Through analyzing the fault cause,it has been found that there exist tree aspects of problem. First, the attenuation manager types and the attenuation volumes of the T/R module test system and the complete machine were different, thus resulted in the test results inconsistency. In addition,the related test of T/R module was only applied a standard excitation according to the technology agreement requirements and no static test, thus the small signals input resulted in the self-excitation. Third, the necessary precautionary measures to avoid overshoot was failed when the amplifier of T/R module was supplied in a pulse power way.
作者 易春兰
出处 《压电与声光》 CSCD 北大核心 2013年第1期144-146,共3页 Piezoelectrics & Acoustooptics
关键词 TR组件 发射波形 波形畸变 脉冲供电 过冲 批次故障 TR module transmitting waveform waveform distortion pulsed power supply overshoot fault of thebatch
  • 相关文献

参考文献2

  • 1郑新;李文辉;潘厚忠.雷达发射机技术[M]北京:电子工业出版社,2006.
  • 2曾天翔.电子设备测试性及诊断技术[M]北京:航空工业出版社,1996.