期刊文献+

深圳市某办公建筑水平百叶外遮阳优化分析 被引量:1

Optimizing Horizontal Louver Sun-shading for Office Buildings in Shenzhen
下载PDF
导出
摘要 以深圳市某办公建筑为例,采用Ecotect软件分析了水平百叶外遮阳对建筑立面太阳辐射的影响。模拟结果得出了在不同板片倾角、不同的百叶中心离墙距离、不同朝向下的夏季太阳直射、散射、总辐射量的变化曲线。并对固定式水平百叶外遮阳的不同板片倾角和百叶离墙距离的模拟结果进行比较分析,得到最佳的百叶倾角和离墙距离,在此基础上提出该建筑的百叶遮阳的最优布置方案。 An office building in Shenzhen is researched as example. Ecatect is utilized to analyze the effect of horizontal louver sunshading to solar radiation on building elevation. The results of simulation show that the curves of incidence, diffuse and total solar radiation in different slat angles, various distances between wall and center of shading, different directions in summer season. Meanwhile, it compared and analyzed the simulation results at different slat angles and distances between wall and slat of fixed shading. The optioned slat angle and distance between slat and wall are obtained, proposing the optimization programs about horizontal louver sun-shading.
出处 《建筑节能》 CAS 2013年第2期37-39,43,共4页 BUILDING ENERGY EFFICIENCY
关键词 水平外遮阳 太阳辐射 优化 horizontal louver sun-shading solar radiation optimizing
  • 相关文献

参考文献1

共引文献5

同被引文献3

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部