期刊文献+

葛洲坝自备电源电站发电机通风系统改造 被引量:4

Upgrading for ventilation system of generator of Gezhouba Self - powered Station
下载PDF
导出
摘要 葛洲坝自备电源电站自投产以来,其水力发电机组的定子温升一直偏高,在夏季竟高达101℃,是发电机安全运行的重大隐患。探讨分析了葛洲坝自备电源电站发电机温度过高的原因,根据分析结果,制定了一系列降低温升的比较方案,经反复研究,决定对通风系统结构实施优化改造,对改造前后的发电机通风状况以及定子的温度进行试验与测量,并将试验与测量结果进行对比。结果表明,通风系统结构的优化改造对改善定子的温度有显著的效果。 Since the operation of Gezhouba Self - powered Station, the stator temperature rise of hydroelectric generating set has been high, and as high as 101 ~C in summer, which is a hidden danger for the safe operation of generator. A series of alterna- tive schemes for reducing temperature rise is developed in accordance with the results of analyzing the cause of the high tempera- ture. The optimization for the ventilation system is determined with the detailed study. The generator ventilation condition and stator temperature before and after the upgrading project are measured and compared. The results show that the optimization and transformation have a significant effect on reducing the stator temperature.
作者 宋珺 杨豆思
出处 《人民长江》 北大核心 2013年第4期69-72,共4页 Yangtze River
关键词 水轮发电机 定子 温升 通风改造 葛洲坝水电站 hydro generator stator temperature rise ventilation upgrading Gezhouba Hydropower Station
  • 相关文献

参考文献6

二级参考文献9

共引文献11

同被引文献25

引证文献4

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部