摘要
近年来,红外碳硫仪在各行业广泛应用,瓷坩埚的大量使用使分析成本提高。本文研究了高频红外碳硫分析仪用瓷坩埚的重复利用问题,试验结果表明:坩埚使用后空白值非常低,用于检测我公司各种样品,结果均稳定可靠,说明瓷坩埚重复利用是可行的,可以节约50%的检测成本。
In recent years, high - frequency IR carbon & sulphur determinator was widely used in various industries, and the use of porcelain crucible increased the analysis cost. The reuse porcelain crucible for high - frequency IR carbon & sulphur determinator was introduced, according to various samples experiments & tests of the company, and the test showed that the blank value of the reused crucible was very low, and the result was stable and reliable. The new methods was feasible, which can decrease 50% test cost.
出处
《广州化工》
CAS
2013年第4期88-89,128,共3页
GuangZhou Chemical Industry
关键词
高频红外碳硫仪
瓷坩埚
重复利用
high -frequency IR carbon & sulphur determinator
porcelain crucible
reused