期刊文献+

基于过采样技术的手持式测力计的设计与实现

Design and Realization of the Handhold Dynamometer Based on Oversampling
下载PDF
导出
摘要 本设计以ATMEL公司高性能的ATmega32单片机为主控单元构成了手持式测力计的硬件系统.前端信号放大电路采用专用的仪表放大器INA126,确保传感器输出的准确性.软件设计中应用过采样技术提高了对前端弱信号采集的精度,从而保证了测力计测输出的精确性.同时,该测力计集测量、显示和报警功能于一体,同时扩展出标准的RS232接口,可以与计算机实现通信,方便数据处理,另外为保证测量精度和适应应用环境,本设计中在软硬件设计方面对可靠性的设计进行了深入的探讨. The design is the hardware of a dynamometer based on Atmega32 which was made in ATMEL. Ltd. In order to ensure exact signal output of the sensor, INA126 is used in the signal amplify circuit. In software design, over sample technology was used. Meanwhile, the dynamometer includes measure, dis- play and alarm. The standard RS232 interface can communicate with the compute. To guarantee accuracy of measurement and adaptation to the environment, a thorough discussion on the software and hardware is conducted.
出处 《陇东学院学报》 2013年第1期23-26,共4页 Journal of Longdong University
关键词 测力计 过采样技术 INA126 dynamometer oversampling INA126
  • 相关文献

参考文献4

二级参考文献13

  • 1BERNHARD E B, BRUCE A W. The design of sima-delta modulation analog-to-digital converters[J]. IEEE Journal of Solid-State Circuits, 1988,23(6) : 1298-1307.
  • 2PILLIP E A, DOUGLAS R H. CMOS Analog Circuits Design[M].北京:电子工业出版社,2002.
  • 3CHU S, SIDNEY B. Multirate filter designs using comb filters [J]. IEEE Transactions on Circuits and Systems,1984,31 (11): 913-924.
  • 4艾费科[英].数字信号处理实践方法[M].北京:电子工业出版社,2003.
  • 5BRIAN P B, BRUCE A W. A low power, area efficient digital filter for decimation and interpolation [ J ]. IEEE Journal of Solid-State Circuits, 1994,29(6 ) : 679-687.
  • 6[4]Foster P.R,Burberry R.A.Antenna probierns in RFID systems,RFID Technology,2001
  • 7丁玉美 高西全 彭学愚.数字信号处理[M].西安:西安电子科技大学出版社出版,2000..
  • 8高攸纲,刁庆安.展望21世纪的环境电磁学及电磁兼容技术(上)[J].邮电设计技术,1999(5):1-5. 被引量:8
  • 9徐士斌.自复保险丝[J].太阳能,1999(2):30-31. 被引量:2
  • 10李建清,黄惟一.改善高分子PTC材料可恢复过流保护性能的老化方法[J].电子元件与材料,1999,18(6):7-8. 被引量:1