3Mulholland J W,Shelton J C, Luo X Y. Blood Flow and Dam-age by the Roller Pumps During Card Input Monary Bypass[J]. Journal of Fluids and Structures,2005 , (20) : 129 — 140.
二级参考文献34
1Asama J,Shinshi T,Hoshi H,et al.A new design for a compact centrifugal blood pump with a magnetically levitated rotor.ASAIO J,2004,50(6):550-556.
2Hoshi H,Asama J,Shinshi T,et al.Disposable magnetically levitated centrifugal blood pump:design and in vitro performance.Artif Organs,2005,29(7):520-526.
3Asama J,Shinshi T,Hoshi H,et al.A compact highly efficient and low hemolytic centrifugal blood pump with a magnetically levitated impeller.Artif Organs,2006,30(3):160-167.
4Locke DH,Swanson ES,Walton JF 2nd,et al.Testing of a centrifugal blood pump with a high efficiency hybrid magnetic bearing.ASAIO J,2003,49(6):737-743.
5Rogers JG,Butler J,Lansman SL,et al.Chronic mechanical circulatory support for inotrope-dependent heart failure patients who are not transplant candidates:results of the INTrEPID Trial.J Am Coll Cardiol,2007,50(8):741-747.
6Maybaum S,Mancini D,Xydas S,et al.Cardiac improvement during mechanical circulatory support:a prospective multicenter study of the LVAD working group.Circulation,2007,115(19):2497-2505.
7Birks EJ,Tansley PD,Hardy J,et al.Left ventricular assist device and drug therapy for the reversal of heart failure.N Engl J Med,2006,355(18):1873-1884.
8Liden H,Karason K,Bergh CH,et al.The feasibility of left ventricular mechanical support as a bridge to cardiac recovery.Eur J Heart Fail,2007,9(5):525-530.
9Gibbon JH Jr.Application of a mechanical heart and lung apparatus to cardiac surgery.Minn Med,1954,37(3):171-185.
10DeBakey ME.Development of mechanical heart devices.Ann Thorac Surg,2005,79(6):S2228-S2231.
4Untaroiu A, Throckmorton A L, Patel S M, et al. Nu- merical and experimental analysis of an axial flow left ventricular assist device: the influence of the diffuser on overall pump performance [ J ]. Artif Organs, 2005,29 (7) :581-591.
5Throckmorton A L, Kapadia J Y, Cb.opski S G, et al. Nu- merical hydraulic and hemolytic evaluation of an intravas- cular axial flow blood pump to mechanically support fontan patients[ J]. Ann Biomed Eng, 2011,39( 1 ) :324-336.
6Zhang J, Gellman B, Koert A, et al. Computational and experimental evaluation of the fluid dynamics and hemo- compatibility of the centrimag blood pump [ J ~. Artif Or- gans, 2006,30( 3 ) : 168-177.
7Bludszuweit C. Model for a General Mechanical Blood Damage Prediction [ J ]. Artif Organs, 1995,19 ( 7 ) : 583- 589.