期刊文献+

Mimics14.0软件在胫骨螺钉外固定架模型建立的初步应用 被引量:1

Preliminary application of Mimics 14.0 software in model construction of external fixation of tibia screw
下载PDF
导出
摘要 目的利用Mimics 14.0软件重建、组合、赋值外固定架螺钉的三维模型,为遴选适宜的外固定架材料创造条件。方法将CT扫描层厚0.625mm的DICOM格式图像1 000张导入Mimics 14.0软件,筛选出胫骨平台下5cm处图片60张进行三维重建,将螺钉扫描后导入胫骨骨干的三维模型中,利用Mimics 14.0软件的自适应装配,赋值功能生成组合模型。结果胫骨生成4 744个三角面片,创建582 750个单元,螺钉生成4 362个三角面片,创建11 868个单元。结论 Mimics 14.0软件可快速、有效生成三维模型,便于Ansys、Abaqus等有限元软件进行分析,为不同材料属性的螺钉的抗拔出力等生物力学研究提供基础。 Objective To utilize the Mimics 14.0 software to reeonstruct,eomblnate and assign the three dimensional model of external fixation screw to create the condition for selecting appropriate materials of external fixation. Methods 1 000 CT images (0. 625 mm) were inputted to the Mimics 14.0 software. 60 images located at 5 cm below tibia plateau were screened to three di- mensional reconstruction. Meanwhile, screws were scanned to input to the three dimensional model of tibia to generate the new com- bined model with the functions of auto-assembling and assigning material. Results The tibia and screw generated 4 744 triangles, 582 750 elements,4 362 triangles, 11 868 elements respectively. Conclusion The Mimics 14.0 software could generate three dimen- sional model rapidly and effectively,which is convenient to be analyzed by finite element software(Ansys, Ahaqus) ,and provides the theoretical basis of biomechanic study on pullout resistance of different screws.
出处 《重庆医学》 CAS CSCD 北大核心 2013年第7期783-785,共3页 Chongqing medicine
关键词 胫骨骨折 外固定器 三维模型 tibia fractures external fixation screw three dimensional model
  • 相关文献

参考文献15

  • 1Bluman EM,Ficke JR,Covey DC. War wounds of the foot and ankle:causes,characteristics,and initial management[J].Foot and Ankle Clinic,2010,(01):1-21.
  • 2Matsuura M,Lounici S,Inoue N. Assessment of external fixator reusability using load-and cycle-dependent tests[J].Clinical Orthopaedics and Related Research,2003,(406):275-281.doi:10.1097/00003086-200301000-00038.
  • 3Agarwal S,Agarwal R,Jain UK. Management of soft-tissue problems in leg trauma in conjunction with application of the Ilizarov fixator assembly[J].Plastic and Reconstructive Surgery,2001,(07):1732-1738.doi:10.1097/00006534-200106000-00014.
  • 4Quenneville CE,Dunning CE. Development of a finite element model of the tibia for short-Duration high-force axial impact loading[J].Computer Methods in Biomechanics and Biomedical Engineering,2011,(02):205-212.
  • 5Gray HA,Zavatsky AB,Taddei F. Experimental validation of a finite element model of a composite tibia[J].Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine,2007,(03):315-324.
  • 6Lei T,Xie L,Tu W. Development of a finite element model for blast injuries to the pig mandible and a preliminary biomechanical analysis[J].J Trauma Acute Care Surg,2012,(04):902-907.
  • 7Vilayphiou N,Boutroy S,Szulc P. Finite element analysis performed on radius and tibia HR-pQCT images and fragility fractures at all sites in men[J].Journal of Bone and Mineral Research,2011,(05):965-973.
  • 8Verhulp E,Van Rietbergen B,Muller R. Micro-finite element simulation of trabecular-bone post-yield behaviour--effects of material model,element size and type[J].Computer Methods in Biomechanics and Biomedical Engineering,2008,(04):389-395.
  • 9Gurgel-Juarez NC,de Almeida EO,Rocha EP. Regular and platform switching:bone stress analysis varying implant type[J].Journal of Prosthodontics,2012,(03):160-166.
  • 10Epari DR,Lienau J,Schell H. Pressure,oxygen tension and temperature in the periosteal callus during bone healing--an in vivo study in sheep[J].Bone,2008,(04):734-739.doi:10.1016/j.bone.2008.06.007.

同被引文献9

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...