摘要
针对广州市轨道交通五号线珠江新城站主体结构不同部位出现的渗漏水现象进行了分析,分别阐述其原因,着重阐述了地铁车站主体结构施工渗漏水的控制方法及堵漏措施,为今后同类工程中渗漏水处理提供了借鉴。
The paper analyzes the water leakage at various parts of the main structure at Zhujiangxincheng Station along 5th Line of Rail Traffic of Guangzhou, and mainly illustrates the controlling methods and measures for leaking stoppage of the main structure of the subway, so as to provide some reference for the water leakage treatment for similar projects in future.
出处
《山西建筑》
2013年第7期95-96,共2页
Shanxi Architecture
关键词
地铁车站
主体结构
渗漏水
控制方法
堵漏措施
subway station
main structure
water leakage
controlling method