高层建筑燃气供应系统中附加压头的影响 被引量:3

Influence of Additional Pressure Head of Gas Supply System in High rise Building
下载PDF
导出
摘要 高层建筑燃气供气系统受高度影响 ,对于不同于空气密度的燃气 ,供气管道会产生较大的附加压头 ,影响供气效果和安全 ,在此 。 Gas supply system is influenced by the height.Gas,whose density is different from that of air,will bring about strong additional pressure head to the gas pipe,which will affect the efficiency and safety of gas supply.Therefore,the concerning technology must be improved and side effect eliminated.
作者 罗义英 尚毅
出处 《河南城建高等专科学校学报》 2000年第3期36-38,共3页 Journal of Henan Urban Construction Junior College
关键词 高层建筑 附加压头 燃气供应系统 供所管道 high rise building additional pressure head
  • 相关文献

参考文献3

  • 1GRI-94/0013 Interior Gas Distribution Technology for Tall Builelings.
  • 2GRI-94/0236 Interior Gas Distribution Technology for Tall Buildings Phase Ⅱ Case Study NOI.Evaluation of AS-In.stalled Versus Enhaneed Gas Distribution System Valley & Apartment.
  • 3杨光,尹衍光,谢翔,王晓东.高层建筑燃气管道设计有关问题的探讨[J].煤气与热力,1999(1):24-27. 被引量:10