给出层间交通电梯可能停站数公式和平均最高反向楼层的广义形式.提出普阿松分布的3种形式.和上行峰值交通一起.为全面给出建筑物的电梯交通配置设计打下了基础。
It is given the formula of probable number of stops of elevator enterfloor traffic and the number of average highest reversal floor. The three forms of the Poisson process is advanced. With up peak traffic, the basis is taken for elevator traffic dispatching design of buildings.