期刊文献+

溧阳抽水蓄能电站水泵水轮机模型验收试验 被引量:7

Model Acceptance Test for the Pump Turbine of Liyang Pumped-storage Power Station
下载PDF
导出
摘要 江苏溧阳抽水蓄能电站水泵水轮机模型验收试验于2012年4月至5月在瑞士洛桑PF2中立试验台进行。简要介绍了模型水泵水轮机和模型试验台,并对主要试验结果进行了分析,试验结果表明,该水泵水轮机主要水力性能指标满足合同要求,水力设计较先进,在正常运行范围内不存在"S"区现象。 The model acceptance test for the pump turbine of Liyang Pumped-storage Power Station is carried out in test rig PF2 (independent) of hydraulic laboratory of LMH, EPFL Lausanne, Switzerland in April to May 2012. The pump-turbine model and test rig are briefly described, and the main test results are analyzed. The analyses show that the hydraulic performances of pump turbine meet the requirements of contract, the hydraulic design is more advanced, and there is no "S" phenomenon within normal operating area.
出处 《水力发电》 北大核心 2013年第3期79-81,共3页 Water Power
关键词 验收试验 水泵水轮机模型 溧阳抽水蓄能电站 acceptance test pump turbine model Liyang Pumped-storage Power Station