随着城市化进程的加剧,填埋场恶臭逐渐成为影响城市生活的重要污染.对于场界范围内的恶臭发生源通常要依靠经验确定,难以对填埋场界范围内的恶臭污染强度分布及变化规律进行科学的描述.利用电子鼻与GPS定位仪对生活垃圾填埋场内的恶臭污染情况进行检测,通过GIS软件作图绘制恶臭污染等强度曲线,对场内强污染源释放点进行确定,发现覆盖膜破损及焚烧火炬尾气排放是造成场内恶臭污染的主要原因.对填埋气产量估算分析表明提高填埋气处理能力是控制恶臭污染的关键.
Odor pollution of landfill site is a serious problem accompanied with the urbanization process that influences city life. Generally, odor emission points in landfill boundary are detected by experience, but the pollution intensity, distribution and variation in the scope of landfill boundary are difficulty to describe. In this research, odor emission points were disclosed with equal odor concentration curves that were delineated using electric nose and GPS instrument. The leakage of landfill gas and exhaust emission from biogas incineration torch was the main cause of the odor pollution in landfill area. Gas production evaluation suggested that the improvement of landfill gas consumption is the key point to control the odor pollution at the landfill site.
出处
《环境科学》
EI
CAS
CSCD
北大核心
2013年第3期842-848,共7页
Environmental Science
基金
北京市教委面上项目(11ZX002
KM201310858003)
北京电子科技职业学院科技重点项目(YZK2012021
YZK2011009
YZKB2010004)
固体废物处理与环境安全教育部重点实验室开放基金项目(SWMES 2010-06)
北京市委
市政府重点工作及区县政府应急项目预启动项目(Z11111005680000)
关键词
填埋场
恶臭污染
电子鼻
填埋气
分析
landfill
odor
electronic nose
landfill gas
analysis