期刊文献+

严重脓毒症患者的容量负荷判断 被引量:8

Assessment of volume load in patients with severe sepsis
下载PDF
导出
摘要 液体复苏一直是严重脓毒症患者治疗中的最基本、最重要原则。及时准确的容量评估是液体复苏治疗的关键。近年来,随着各种血流动力学监测技术的发展和各种容量反应性评估方法在临床中的广泛应用,以及对容量评估指标理解的不断深入,严重脓毒症患者容量评估及液体复苏的理论和实践都得到了进一步完善和提高。 Fluid resuscitation has been the most fundamental and important principle in the treatment of patients with severe sepsis. Timely and accurate volume assessment is the key to the treatment of fluid resuscitation. In recent years, with various hemodynamic monitoring technology development and volume responsiveness methods widely used in clinical, as well as parameters of volume status to understand in depth, the theory and practice in the field of volume assessment and fluid resuscitation in patients with severe sepsis have been further improved and enhanced.
出处 《中国急救医学》 CAS CSCD 北大核心 2013年第2期98-100,共3页 Chinese Journal of Critical Care Medicine
关键词 容量反应性 液体复苏 血流动力学监测 Volume responsiveness Fluid resuscitation Hemodynamic monitoring
  • 相关文献

参考文献18

  • 1Rivers E, Nguyen B, Havstad S, et al. Early goal - directed therapy in the treatment of severe sepsis and septic shock [ J ]. N Engl J Med, 2001, 345(19) : 1368 -1377.
  • 2Puskarich MA, Marchick MR, Kline JA, et al. One year mortality of patients treated with an emergency department based early goal directed therapy protocol for severe sepsis and septic shock: a before and after study[J]. Crit Care, 2009, 13(5) : R167.
  • 3Focht A, Jones AE, Lowe TJ. Early goal - directed therapy: improving mortality and morbidity of sepsis in the emergency department[J]. Jt Comm J Qual Patient Saf, 2009, 35(4) : 186 - 191.
  • 4BeUamy MC. Wet, dry or something else [ J ]. Br J Anaesth, 2006, 97 (6) : 755 - 757.
  • 5Marik PE, Baram M, Vahid B. Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares[J]. Chest, 2008, 134(1) : 172 -178.
  • 6Osman D, Ridel C, Ray P, et al. Cardiac filling pressures are not appropriate to predict hemodynamie response to volume challenge [ J ]. Crit Care Med, 2007, 35 ( 1 ) : 64 - 68.
  • 7Mieharcl F, Alaya S, Zarka V, et al. Global end - diastolic volume as an indicator of cardiac preload in patients with septic shock [J]. Chest, 2003, 124(5) : 1900 -1908.
  • 8Michard F, Boussat S, Chemla D, et al. Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure[ J]. Am J Respir Crit Care Med, 2000, 162(1) : 134 -138.
  • 9Marik PE, Cavallazzi R, Vasu T, et al. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature [J]. Crit Care Med, 2009, 37(9) : 2642 -2647.
  • 10Barbier C, Loubieres Y, Schmit C, et al. Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients [ J ]. Intensive Care Med, 2004, 30(9) : 1740 - 1746.

同被引文献84

引证文献8

二级引证文献86

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部