摘要
在大港油田炼油厂空分装置改扩建工程中 ,针对压缩机基础的超标振动现象 ,分析原因并提出简单、安全、有效的补救措施 ,使振动情况大为改观 ,为主体工程
The caused of vibration exceeded to standard on compresor foundation was analyzed in the expasion project of Dagang oilfield refinery air separation workshop.A simple,safe & effective trouble shooting was established which make sure that 400 thousand t/a diesel hydrotreatment device start-up on schedule.
出处
《石油工程建设》
2000年第5期45-46,49,共3页
Petroleum Engineering Construction