期刊文献+

钛及钛合金X射线应力测试参数的选择 被引量:11

Selection method of X-ray diffraction stress measurement parameters for titanium and titanium alloy
下载PDF
导出
摘要 针对钛及钛合金X射线应力测试中衍射峰强度低、峰形差、测试结果波动范围大和准确度低等问题,通过对标准零应力试样和标准应力试样的X射线应力测试,研究了钛及钛合金X射线应力测试中准直器直径、计数时间和计数次数变化对衍射峰强度、净峰强度、半高宽、应力测试结果的影响规律,在此基础上确定了钛及钛合金X射线应力测试参数的选择方法,并对钛合金电子束焊接头的残余应力进行了测试.结果表明,随着准直器直径增大和计数时间增长,衍射峰强度增大,衍射峰形改善,测试结果准确性提高;随着计数次数增加,衍射峰形改善,测试结果准确性提高;所确定的测试参数对钛合金电子束焊接头残余应力测试的结果满足相关标准要求. Considering the low intensity of diffraction peak,bad diffraction profile,wide fluctuation range and low accuracy of the stress measurement results for titanium and titanium alloy,the effects of aperture diameter,exposure time,and exposure number on the intensity of X-ray diffraction peak,net intensity,full width at half maximum,and the stress measurement results were investigated through the X-ray stress measurement of free stress standard sample and high stress standard sample.On this basis,the selection method of X-ray diffraction stress measurement parameters for titanium and titanium alloy was decided and used in measuring the residual stresses in TC4 welded joint.Results show that with the increase of aperture diameter and exposure time,the intensity of X-ray diffraction peak increases,both the diffraction profile and the accuracy of the test results are improved.What's more,with the increase of exposure number,the diffraction profile and the accuracy of the test results are also improved.The measurement results of residual stresses in TC4 welded joint meet the requirements of the related standards.
出处 《焊接学报》 EI CAS CSCD 北大核心 2013年第2期31-34,39,共5页 Transactions of The China Welding Institution
基金 国家自然科学基金重点资助项目(50935008)
关键词 钛合金 X射线应力测试 测试参数 titanium alloy X-ray stress measurement measurement parameter
  • 相关文献

参考文献6

  • 1Casavola C, Pappalettere C, Tattoli F. Experimental and numeri- cal study of static and fatigue properties of titanium alloy welded joints[J]. Mechanics of Materials, 2009, 41:231 -243.
  • 2Tsay L W, Tsay C Y. The effect of microstructures on the fatigue crack growth in Ti-6AI-4V laser welds[ J]. International Journal ofFatigue, 1997, 19(10) : 713 -720.
  • 3吕克茂.残余应力测定的基本知识——第四讲 X射线应力测定方法(二)[J].理化检验(物理分册),2007,43(8):428-432. 被引量:6
  • 4Ruth E. Metals Handbook[ M]. Ohio: Ohio American Society for Metals, 1986.
  • 5Brouno G, Dunu B D. Surface and bulk residual stress in Ti6A14V welded aerospace tanks[ J]. Journal of Pressure Vessel Technolo- gy, 2004, 126(3) : 284 -292.
  • 6Zhang Y L, Lia J Y, Wang J, et aL X-ray diffraction characteris- tics of five materials for stress measurement [ J ]. Journal of Strain Analysis for Engineering Design, 2010, 45 (4) : 319 - 328.

二级参考文献6

  • 1李家宝.机械工程材料测试手册 物理金相卷,第三篇,第7章[M].沈阳:辽宁科学技术出版社,1999.
  • 2Bourniquel B,Feron J.Proc.1st Int.Conf.on Residual Stresses[C].DGM Informations gesellschaft,1987:275.
  • 3GB 7704-1887 X射线应力测定方法[S].
  • 4Cullity B D.Elements of X-ray diffraction[M].Massachusetts,U.S.A.London,England:Addison-Wesley Publishing Company,Inc.Reading,1978:157.
  • 5何家文.提高淬火钢X射线应力测定准确度(兼评平行光束法)[R].西安:西安交通大学,1975.
  • 6徐寒冰,盖秀颍,宋小平,李家宝.X射线应力测定中的交相关定峰法[J].理化检验(物理分册),1998,34(7):16-18. 被引量:5