摘要 目的比较全髋关节置换术(total hip arthroplasty,THA)中使用3种不同硬对硬界面后,2年内血清钴、铬金属离子浓度的变化,以及临床疗效有无差异。方法 90例THA患者分为陶瓷对陶瓷(COC)、陶瓷对金属(COM)、金属对金属(MOM)3组,每组30例。术前,术后3、6、12、24月检测血清钴、铬金属离子浓度,进行Harris评分,对患髋进行X片连续性观察和彩超检查。结果 3组术后24月患髋Harris评分达优率均为100%,连续X片显示髋臼假体周围未见透亮线、骨溶解等,彩超均未发现炎性假瘤。术后COM组和MOM组内金属离子浓度迅速升高,至12月时变化趋于平稳,并表现出下降趋势。但MOM组中铬离子浓度则继续上升,24月与12月时比较差异具有统计学意义(上升了0.48μg/L,P=0.021)。术后各时间点COC组相对恒定,MOM组钴、铬金属离子浓度大于COC组和COM组(P<0.05)。结论 3种硬对硬界面术后功能恢复好,无炎性假瘤、骨溶解的发生,都取得了满意的临床效果。COM血清钴、铬金属离子浓度低于MOM,高于COC。 Objective To compare the clinical efficacy and serum concentrations of cobalt, chromium metal ion in three different hard-on-hard bearings after total hip arthroplasty at 2-years postoperatively. Methods Ninety (90) THA patients were divided into ceramic-on-ceramic (COC), ceramic-on-metal (COM), metal-owmetal (MOM) group (n:30 in each group). At preoperative and 3, 6, 12, 24 months postoperative 5 time points, serum concentrations of cobalt and chromium metal ion were measured, Harris hip score was evaluated, X-rays and color doppler ultrasound examination of the ipsilateral hip also were observed. Results The excellent rates of Harris hip score were 100% in three groups. Continuous X rays showed no radiolucent line around the acetabular component, no osteolysis, and no inflammatory pseudotumor. After the THA operation, the metal ion levels in COM and MOM groups increased rapidly, and stabilized at 12 months, then showed a downward trend, but the chromium ion level of MOM continued to rise at 24 months, with a significant difference when compared with that at 12 months (an increase of 0.48 /,g/L, P=0. 021). The serum concentrations of metal ion in COC group were relatively constant at all time points, and the cobalt, chromium ion levels of MOM group were significantly higher than those of COC and COM group. Conclusion The postoperative functional recovery of the three hard owhard bearings all were good, and no inflammatory pseudotumor and osteolysis were found. The serum levels of cobalt, chromium ion of COM were lower than those of MOM, but higher than those of COC.
出处 《四川大学学报(医学版)》 CAS CSCD 北大核心 2013年第2期218-221,230,共5页 Journal of Sichuan University(Medical Sciences)
关键词 全髋关节置换术金属离子 陶瓷对金属 炎性假瘤 Total hip arthroplasty Metal ion Ceramic-on-metal Inflammatory pseudotumor
  • 相关文献

参考文献19

  • 1Yilmaz E, Mehmet B. Indications, contraindications and complications of hip arthroplasty. J Orthop Trauma, 2009; 2 (1) :8-15.
  • 2Ha YC, Kim SY, Kim HJ, etal. Ceramic liner fracture after cementless alumina-on-alumina total hip arthroplasty. Clin Orthop Relat Res,2007 ;458(5) :106-110.
  • 3Kenny M, Christopher V, Kace AE, et al. Incidence of ' squeaking' after ceramic-on-ceramic total hip arthroplasty. Clin Orthop Relat Res,2010;468(2) :413-417.
  • 4Park YS, Young WM, Seung JL, et al. Early osteolysis following second-generation metal-on-metal hip replacement. J Bone Joint Surg(Am) ,2005;87(7) :1515-1521.
  • 5Kwon YM, Thomas P, Summer P, et al. Pseudotumours following metal-on-metal hip resurfacing arthroplasty:metal ion and lymphocyte proliferation study. J Bone Joint Surg (Br), 2011 ;93-B(suppl I ) :66-67.
  • 6Firkins PJ, Tipper JL, Ingham E, etal. A novel low wearing differential hardness, ceramic-on-metal hip joint prosthesis. J Biomech, 2001 ; 34(10) : 1291-1298.
  • 7Isaac GH, Brockett C, Breckon A, et al. Ceramic-on-metal bearings in total hip replacement: whole blood metal ion levels and analysis of retrieved components. J Bone Joint Surg (Br), 2009;91B(9) :1134-1141.
  • 8Zywiel MG, Sayeed SA, Johnson AJ, et al. Survival of hard on-hard hearings in total hip arthroplasty: a systematic review. Clin Orthop Relat Res,2011 ;469(6):1536-1546.
  • 9Flugsrud GB, Nordsletten L, Espehaug B, et al. The impact of body mass index on later total hip arthroplasty for primary osteoarthritis: a cohort study in 1.2 million persons. ArthritisRheum,2006;54(3) :802-807.
  • 10Lewinnek GE, Lewis JL, Tarr R, et al. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am, 1978;60(2) :217-220.

同被引文献75

引证文献3

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部