17mm St.Jude Regent瓣术后中远期临床效果和在体血流动力学评价

Mid-long-term Clinical Results and Hemodynamic Evaluation of Aortic Valve Replacement with 17 mm St. Jude Medical Regent Valve
原文传递
导出
摘要 目的观察17mm St.Jude Regent机械瓣置入人体后中远期临床效果,测量其有效瓣口面积,评价是否发生瓣膜-患者不匹配(prosthesis-patient mismatch,PPM)现象,并探索PPM现象对术后患者心功能的影响。方法 44例心脏瓣膜病患者接受二尖瓣及主动脉瓣置换术,所有患者因主动脉瓣环小而置入17mm St.JudeRegent机械瓣。对该组患者进行随访研究,分别于术前及术后12~55月,运用心脏彩色超声心动图测量17mmSt.Jude Regent机械瓣的在体有效瓣口面积和各血流动力学指标,并采用NYHA分级标准评估患者术后心功能。结果全部患者通过门诊或电话完成随访,其中有39例(88.6%)患者在术后12~55月完成心脏彩色超声心动图检查,随访期内共有1例患者(2.27%)发生心功能衰竭死亡;按照当前国际有效瓣口面积指数(effective orifice areaindex,EOAI)标准(EOAI≤0.85cm2/m2即可出现PPM),33例患者(82.1%)出现PPM,其中13例患者(30.8%)发生严重PPM(EOAI≤0.65cm2/m2);术后患者主动脉瓣跨瓣压差、左室质量(LVmass)及左室质量指数(LVmassI)均较术前降低(P<0.05),按照NYHA分级标准评价患者术后心功能示恢复良好(P<0.05)。结论①小主动脉瓣环患者采用17mm St.Jude Regent瓣避免了行主动脉瓣环扩大术,且能取得较好的中远期临床疗效。②按照当前国际EOAI标准,PPM现象不会严重影响17mm St.Jude Regent瓣膜置换术后患者的中远期疗效。 Objective To investigate the mid-long-term clinical results of aortic valve replacement with 17 mm St. Jude medical regent valve with hemodynamic evaluation including the measurement of effective orifice area, the occurrence of prosthesis-patient mismatch (PPM) and its affect on heart function. Methods There were 44 patients accepted aortic valve replacement with 17 mm St. Jude medical regent valve because of small aortic annulus. Before the operation and during the postoperative follow-up, color doppler echocardiography was used to measure the hemodynamic parameters, such as left ventricular mass (LVmass), effective orifice area (EOA) and effective orifice area index (EOAI), etc.. Results Transthoracic echocardiographic data were obtained from 39 of 44 patients (88.6%)at 12 55 months after surgery. One (2. 27%) died of heart failure in 1 year. According to the current standard of PPM (EOAI〈0.85 cm2/m2), a3 cases (82.1%) had PPM, 13 cases (30.8M) had severe PPM with an EOAI≤ 40.65 cm2/m2. After the operation, there were significant decreases in LVAo PG (19-1-8) mmHg and left ventricular mass index (LVmass I ) (86.6 23.3) g/m2 (P〈0.05). The assessment for physical capacity according to NYHA classification: 41 patients improved to class 11 or better and 2 patients improved to classIII (P%0.05). Conclusion The patients with small aortic annulus may obtain satisfactory clinical results after AVR with 17 mm St. Jude medical regent valve, PPM seems not affect the mid-long-term results.
出处 《四川大学学报(医学版)》 CAS CSCD 北大核心 2013年第2期316-318,326,共4页 Journal of Sichuan University(Medical Sciences)
关键词 瓣膜-患者不匹配 17mm St.Jude Regent机械瓣 主动脉瓣置换术 血流动力学 Prosthesis-patient mismatch 17-mm St. Jude Medical Regent Aortic valve replacementHemodynamics
  • 相关文献

参考文献10

  • 1Pibarot P, Dumesnil JG. Prosthesis-patient mismatch: definition, clinical impact, and prevention. Heart, 2006; 92 (8):1022- 1029.
  • 2Castro LJ, Arcidi JM Jr, Fisher AL, et al. Routine enlargement of the small aortic root: a preventive strategy to minimize mismatch. Ann Thorac Surg,2002;74(1):31-36.
  • 3Bach DS, Cartier PC, Kon ND, et al. Impact of implant technique following freestyle stentless aortic valve replacement. Ann Thorac Surg,2002;74(4) :1107-1113.
  • 4Garatti A, Mori F, Innocente F, et al. Aortic valve replacement with 17-mm mechanical prostheses: is patient- prosthesis mismatch a relevant phenomenon? Ann Thorac Surg,2011;91(1) :71-77.
  • 5Rahimtoola SH. The problem of valve prosthesis-patient mismatch. Circulation, 1978 ; 58 (1) : 20-24.
  • 6赵东,王春生,洪涛,丁文军.小主动脉瓣环患者应用Regent机械瓣术后心功能变化的评价[J].复旦学报(医学版),2006,33(2):251-253. 被引量:6
  • 7Taniguchi S, Noguchi M, Onohara D, et al. Aortic valve replacement with 17-mm St. Jude Medical Regent prosthetic valves for a small ealeifi ed aortic annulus in elderly patients. Gen Thorae Cardiovasc Surg, 2010 ; 58(10) : 506-510.
  • 8Sato M, Suenaga E, Koga S, et al. Aortic valve replacement with smaller valve size. Asian Cardiovasc Thorac Ann, 2011;19 (5) :314-319.
  • 9程力剑,张尔永,郭应强.19mm St.Jude Regent瓣有效瓣口面积和血流动力学的早期在体研究[J].中国胸心血管外科临床杂志,2007,14(4):256-260. 被引量:8
  • 10李继勇,张健群,伯平,曹向戎,陈宝田.小主动脉瓣环患者机械瓣置换术后中期疗效分析[J].中国胸心血管外科临床杂志,2008,15(5):329-332. 被引量:6

二级参考文献32

  • 1王红兵,周更须,郑奇军,陈文生,蔡振杰,刘维永.小主动脉瓣环患者主动脉瓣置换术41例[J].中国胸心血管外科临床杂志,2006,13(1):52-53. 被引量:8
  • 2Tasca G,Brunelli F,Cirillo M,et al.Impact of valve prosthesis-patient mismatch on left ventricular mass regression following aortic valve replacement[J].Ann Thorac Surg, 2005,79(2):505
  • 3Rahimtoola SH.The problem of valve prosthesis-patient mismatch[J].Circulation, 1978,58(1):20
  • 4Takai H,Yamachika S,Hazama S,et al.Consideration of prosthesis-patient mismatch and left ventricular mass regression after implantation of the Carpentier-Edwards pericardial valve in elderly Japanese patients: body surface area may be irrelevant[J].J Artif Organs, 2004,7(4):203
  • 5Pibarot P,Dumesnil JG.Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention[J].J Am Coll Cardiol,2000(36):1131
  • 6Okumiya, Toshika IN, Mitsuko D,et al.Evaluation of intravascular hemolysis with erythrocyte creatine in patients with cardiac valve prostheses[J].Chest, 2004,(1):13
  • 7Blais C,Dumesnil JG,Baillot R,et al.Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement[J].Circulation, 2003,26;108(8):983
  • 8Bach DS,Goldbach M,Sakwa MP,et al.Hemodynamics and early performance of the St.Jude Medical Regent aortic valve prosthesis[J].J Heart Disease, 2001(10):436
  • 9Rahimtoola SH.The problem of valve prosthesis-patient mismatch.Circulation,1978,58(1):20-24.
  • 10Milano AD,De Carlo M,Mecozzi G,et al.Clinical outcome in patients with 19-mm and 21-mm St.Jude aortic prostheses:comparison at long-term follow-up.Ann Thorac Surg,2002,73(1):37-43.

共引文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部