摘要 本文提出一种利用时间序列法(ARIMA模型)进行震前电离层异常探测的新方法.首先,对比分析了该方法与传统探测方法(四分位距法、滑动时窗法)预测TEC背景值的精度.结果表明,时间序列法预测背景值的精度要明显高于传统方法,且预报背景值的平均偏差要比传统方法小2倍左右,说明传统探测方法预测的背景值具有较大系统偏差.为更准确地探测震前电离层扰动,除了得到准确的参考背景值,还需得到更加合理的探测限值,由此本文提出一种更为合理的限差确定策略.最后,以2012年1月10日苏门答腊岛7.2级地震为例,利用该方法分析了其震前电离层的异常扰动情况,并验证了该方法的有效性,实验结果表明:在震前第13天、第8~9天、第1~2天和地震当天电离层均会发生较为明显的异常.而且,其正异常(观测值高于正常值)一般发生在震中以北,距发震时间相对较远;负异常(观测值低于正常值)则在震中各方向均会出现,且距发震时间较近.同时,通过对异常结果分时段统计,发现在发震时刻前,距发震时刻越近的时段发生异常的频率越高,此规律将会对未来更为准确的预报发震时段提供重要参考. This paper proposed a new method for detection of pre-earthquake ionospheric anomalies using time series analysis based on the Autoregressive Integrated Moving Average (ARIMA) model. Firstly, we compared the precision of this new method with the traditional ones, namely the Inter Quartile Range (IQR) method and the sliding window method, in predicting the TEC reference background values. The results show that the precision of the former is obviously better than the latter, while the average prediction residual errors of the former are twice smaller than the latter. To detect pre-earthquake ionospheric anomalies more accurately, besides precise reference background value, its reasonable error range is also needed.Therefore, this paper put forward a new method to calculate the reference background valuers upper and lower bounds. Finally, the earthquake happened in Sumatra on January 10, 2012 was taken as example. We analyzed its pre-earthquake ionospheric anomalies and proved the effectiveness of the new method. The results show that obvious ionospheric anomalies appeared on the 13th, 8th to 9th and 1st to 2nd days before the earthquake as well as several hours during the day when the earthquake happened. Furthermore, positive anomalies (observational values higher than normal ones) generally appeared to the north of the epicenter and are much earlierbefore norma occurr times earthq likely the earthquake occurrence, while the negative ones (observation values lower than the 1) occurred in any direction to the epicenter, and close to the moment the earthquake ence. Through statistics for the frequency of ionospheric anomalies occurred at different of the day, we have also found a valuable law that the closer the time of the day before the uake moment, the higher the occurrence frequency of the ionospheric anomalies, which is to be an important reference to the more accurate earthquake prediction in the future.
出处 《地球物理学报》 SCIE EI CAS CSCD 北大核心 2013年第2期441-449,共9页 Chinese Journal of Geophysics
基金 国家自然科学基金(41074024) 创新研究群体科学基金(41021061)联合资助
关键词 时间序列法 TEC 地震 电离层异常 ARIMA模型 Time series analysis, TEC prediction, Earthquake, Ionosphere anomaly, ARIMA
  • 相关文献

参考文献16

  • 1Astafyeva E, Heki K. Vertical TEC over seismically active region during low solar activity. J. Atmos. Sol.-Terr. Phys., 2011.73(13):1643-1652.
  • 2Chavez O, Pérez-Enríquez R, Cruz-Abeyro J A, et al. Detection of electromagnetic anomalies of three earthquakes in Mexico with an improved statistical method. Nat. Hazards Earth Syst. Sci., 2011,11:2021-2027, doi:10.5194/nhess-11-2021-2011.
  • 3Hasbi A M, Mohd Ali M A, Misran N. Ionospheric variations before some large earthquakes over Sumatra. Nat. Hazards Earth Syst. Sci., 2011,11:597-611, doi:10.5194/nhess-11-597-2011.
  • 4Oyama K I, Kakinami Y, Liu J Y, et al. Reduction of electron temperature in low latitude ionosphere at 600 km before and after large earthquakes. J. Geophys. Res., 2008 113: A11317, doi:10.1029/2008ja013367.
  • 5Barnes R A, Leonard R S. Observations of ionospheric disturbances following the Alaska earthquake.J. Geophys. Res., 1965, 70: 1250-1253.
  • 6Pulinets S A, Contreras A L, Ciraolo L, et al. Total electron content variations in the ionosphere before the Colima, Mexico, earthquake of 21 January 2003. Geofisica Internacional, 2005, 44(4): 369-377.
  • 7Datchenko E A, Ulomov V I, Chernyshova C P. Electron density anomalies as the possible precursor of Tashkent earthquake. Dokl. Uzbek. Acad. Sci., 1972, 12: 30-34.
  • 8孟泱,王泽民,鄂栋臣.基于GPS数据的地震前电离层TEC异常研究[J].武汉大学学报(信息科学版),2008,33(1):81-84. 被引量:17
  • 9林剑,吴云,祝芙英,乔学军,周义炎.基于GPS探测汶川地震电离层TEC的异常[J].地球物理学报,2009,52(1):297-300. 被引量:46
  • 10蔡军涛,陈小斌,赵国泽,詹艳,汤吉.地震前兆:电离层F_2层异常[J].地球物理学进展,2007,22(3):720-728. 被引量:17

二级参考文献80

  • 1滕吉文.21世纪地球物理学的机遇与挑战[J].地球物理学进展,2004,19(2):208-215. 被引量:23
  • 2吴云,乔学军,周义炎.利用地基GPS探测震前电离层TEC异常[J].大地测量与地球动力学,2005,25(2):36-40. 被引量:81
  • 3丁鉴海,索玉成,余素荣.地磁场与电离层异常现象及其与地震的关系[J].空间科学学报,2005,25(6):536-542. 被引量:56
  • 4滕吉文.当代中国地球物理学向何处去[J].地球物理学进展,2006,21(2):327-339. 被引量:36
  • 5张强,吴云,林剑,周义炎,杨少敏,李德前.震前电离层TEC异常分析[J].大地测量与地球动力学,2007,27(3):91-96. 被引量:17
  • 6Pulinets S A,et al. Main phenomenological features of ionospheric precursors of strong earthquakes [ J ]. Journal of Atmospheric and Solar-Terrestrial Physics, 2003,65 : 1 337 - 1 347.
  • 7Sorokina V M,Chmyrevb V M and Yaschenko A K. Theoretical model of DC electric field formation in the ionosphere stimulated by seismic activity [ J]. Journal of Atmospheric and Solar-Terrestrial Physics, 2005, 67 : 1 259 - 1 268.
  • 8Wilson B D, et al. Subdaily northern hemisphere ionospheric maps using an extensive network of GPS receivers [ J ]. Radio Science, 1999,30:639.
  • 9Ondoh T. Seismic-ionosphere effects [ A ]. Atmospheric and Ionospheric Electromagnetic Phenomena associated with Earthquakes[ C ]. Tokyo: Terra Scientific Publishing Company, 1999:789 - 803.