摘要 To study and analyze reconstruction parameters in 99mTc-Trodat-l SPECT(Tomography EmissionComputed Single-Photon) brain semi-quantitative analysis,and the outlined methods of ROIs(regions of interests). The 99mTc-trodat-l SPECT brain imaging was processed,and the ROIs were outlined four times from December 2009 to July 2011.The results for each method were analyzed and compared to improve our experience.There was no statistically significance between the outlined number of pixel in both sides of the cerebellum and the ratio of the radioactive counts.From LEHR and FAN beam collimator,the average ratio became better with increasing the outlining method,especially the fourth time.It could be estimated that striatum mean volume(±SD) was(39.51±9.54 ml,in the range of 19.97-51.98 mL) and mean weight(±SD) was(44.09±10.64 g in the range of 22.28-58.01 g).The details of image processing and data analysis should not be ignored to outline appropriate methods,and withstand the repetitive inspection.The total striatum was outlined and its volume and weight was analyzed. To study and analyze reconstruction parameters in ^(99m)Tc-Trodat-l SPECT(Tomography EmissionComputed Single-Photon) brain semi-quantitative analysis,and the outlined methods of ROIs(regions of interests). The ^(99m)Tc-trodat-l SPECT brain imaging was processed,and the ROIs were outlined four times from December 2009 to July 2011.The results for each method were analyzed and compared to improve our experience.There was no statistically significance between the outlined number of pixel in both sides of the cerebellum and the ratio of the radioactive counts.From LEHR and FAN beam collimator,the average ratio became better with increasing the outlining method,especially the fourth time.It could be estimated that striatum mean volume(±SD) was(39.51±9.54 ml,in the range of 19.97-51.98 mL) and mean weight(±SD) was(44.09±10.64 g in the range of 22.28-58.01 g).The details of image processing and data analysis should not be ignored to outline appropriate methods,and withstand the repetitive inspection.The total striatum was outlined and its volume and weight was analyzed.
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2012年第6期355-360,共6页 核技术(英文)
关键词 半定量分析 SPECT 纹状体 投资回报率 中国 平均体重 断层扫描 成像处理 Tomography Emission-Computed Single-Photon Image enhancement ^(99m)Tc-trodat-1 Striatum
  • 相关文献

参考文献13

  • 1Mozley P D, Stubbs J B, Plossl K, et al. J Nucl Med, 1998, 39: 2069-2076.
  • 2Kushner S A, McElgin W T, Kung M P, et al. J Nucl Med, 1999, 40: 150-158.
  • 3Jongen C, de Bruin K, Beekman F, et al. Eur J Nucl Med Mol Imaging, 2008, 35: 1692-1698.
  • 4Davis M R, Votaw J R, Bremner J D, et al. J Nucl Med, 2003, 44" 855-861.
  • 5Masilamoni G, Votaw J, Howell L, et al. Exp Neurol, 2010, 226: 265-273.
  • 6Shi J, Zhao LY, Copersino M L, et al. Eur J Pharmacol, 2008, 579: 160-166.
  • 7Troiano A R, Schulzer M, de la Fuente-Fernandez R, et al. Synapse, 2010, 64: 146-151.
  • 8Yu X, Liu M, Fan Y, et al. J Biomed Eng, 2007, 24: 210-214.
  • 9Booij J, Tissingh G, Boer G J, et al. J Neurol Neurosurg Psychiatry. 1997, 62: 133-140.
  • 10Booij J, Korn P, Linszen D H, et al. Eur J Nucl Med, 1997, 24: 674-677.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部