摘要 采用HP-INNOWAX毛细管柱、气相色谱氢火焰离子化检测器测定工业废气和废水中的N,N-二甲基甲酰胺,可能共存的丙酮、乙醇和乙酰丙酮均对测试无干扰。方法在0.939 mg/L~75.1 mg/L范围内线性良好,对工业废水、无组织排放工业废气和有组织排放工业废气中N,N-二甲基甲酰胺的检出限分别为0.47 mg/L、0.16 mg/m3和0.31 mg/m3,标准溶液平行测定的RSD为1.9%~2.2%,废水样品加标回收率为94%~97%。 A capillary gas chromatographic method has been developed for determination of N,N-dimethyl- formamide in industrial waste air and waste water. An HP-INNOWAX column was employed. Quantitative analy- sis was carried out by means of hydrogen flame ionization detector (FID). The results indicated that the coexis- tence of acetone, ethanol and acetyl acetone had no interference with the test. Good linearity was obtained be- tween the concentration range of 0.939 mg/L - 75.1 mg/L. The detection limits come to be 0.47 mg/L for in- dustrial waste water, 0. 16 mg/m^3 for out of control exhaust gas and 0. 31 mg/m3 for stationary source emission. RSD of standard solution parallel determination ranged from 1.9% to 2.2%. Spiked recoveries of waste water sample ranged from 94% to 97%.
出处 《环境监测管理与技术》 2013年第1期43-45,共3页 The Administration and Technique of Environmental Monitoring
关键词 N N-二甲基甲酰胺 毛细管柱 气相色谱法 工业废气 废水 N, N-dimethylformamide Capillary column Gas chromatography Industrial waste air Wastewater
  • 相关文献

参考文献6

二级参考文献3

  • 1国家环境保护局《空气和废气监测分析方法》编写组.空气和废气监测分析方法[M].北京:中国环境科学出版社,1990.325-360.
  • 2国家环保局《水和废水监测分析方法》编委会.水和废水监测分析方法(第3版)[M].北京:中国科学技术出版社,1999.82-85.
  • 3杭世平.空气中有害物质的测定方法[M]人民卫生出版社,1986.

共引文献19

同被引文献53

引证文献9

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部