摘要 分析影响公路隧道火灾灭火及冷却供水强度的主要因素。根据近年来国内外的部分公路隧道汽车火灾实验数据,以及热平衡模型,计算不同规模火灾的灭火供水强度、泡沫供给强度和冷却供水强度。结果表明,小型、中型和大型公路隧道火灾的理论供水强度分别为0.35、0.40、1.20L/(s·m2);隧道顶部衬砌的理论冷却强度为0.20L/(s·m2),实际冷却强度为0.40L/(s·m2)。 The main factors affecting the highway tunnel fire ex tinguishing and cooling agent supply intensity were analyzed. According to the experimental data of highway tunnel fire in China and other countries, and thermal equilibrium model, the extinguishing water supply intensity, foam supply intensity and cooling agent supply intensity for different fire scale were calcu late& Results showed that the theoretical intensity of small, medium and large fire is 0. 35,0. 40,1. 20 L/(s . m^2 ) ; The the oretical cooling intensity of tunnel top lining is 0. 20 L/(s .m^2), while the actual cooling intensity is 0.40 L/(s.m^2).
作者 曹鏐 李本利
出处 《消防科学与技术》 CAS 北大核心 2013年第2期180-182,共3页 Fire Science and Technology
关键词 公路隧道 火灾 灭火剂 供给强度 highway tunnel fire extinguishing agent supply intensity
  • 相关文献

参考文献5

二级参考文献44

  • 1耿惠民,王铁强.汽车火灾的研究[J].消防科学与技术,2004,23(6):596-599. 被引量:46
  • 2陆洲导,朱伯龙,周跃华.钢筋混凝土简支梁对火灾反应的试验研究[J].土木工程学报,1993,26(3):47-54. 被引量:64
  • 3金贤玉,钱在兹,金南国.混凝土受火时温度分布的试验研究[J].浙江大学学报(自然科学版),1996,30(3):286-294. 被引量:13
  • 4Butcher E G,Langdon-Thomas G J,Bedford G K.Fire and Carpark Buildings-Fire Note 10[R].Fire Research Station,London,1968.
  • 5Burgi H.Swiss Tests on Fire Behaviour in Enclosed and Underground Car Parks[J].Fire International,1971,(33):64-77.
  • 6Gewain R G.Fire Experience and Fire Tests in Automobile Parking Structures[J].Fire Journal,1973,67(4):50-54.
  • 7Bennetts I D,Proe D,Lewins R,et al.Open-Deck Car Park Fire Tests[R].BHP Steel International Group,Long Products Division,Whyalla,S.Auat,1985.
  • 8BHP.Fire and Unprotected Steel in Closed Carparks[R].BHP Melbourne Research Laboratories,Melbourne,1987.
  • 9Mangs J,Keski-Rahkonen O.Characterisation of the Fire Behaviour of a Burning Passenger Car.Part Ⅰ:Car fire experiments[J].Fire Safety Journal,1994,23(1):17-35.
  • 10Steinert C.Smoke and Heat Production in Tunnel Fires[C].International Conference on Fires in Tunnels,Swedish National Testing and Research Institute,Boras,Sweden,1994:123-137.

共引文献30

同被引文献20

引证文献4

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部