摘要 目的:探讨相差显微镜与UF-100尿沉渣仪在鉴别肾小球源性血尿和非肾小球源性血尿中的临床应用价值。方法:利用相差显微镜BX51和UF-100尿沉渣仪分别对189例血尿标本进行检测分析。相差显微镜检查按3种判断标准进行尿红细胞形态分析。结果:畸形红细胞总数≥70%且畸形红细胞种类≥3种,或者棘形红细胞≥5%诊断肾小球性血尿的敏感性81.1%,特异性89.1%,明显优于其余两种标准。UF-100的敏感性(91.6%)高于相差显微镜(81.1%),相差显微镜的特异性(84.8%)明显高于UF-100(58.7%)。结论:相差显微镜和UF-100尿沉渣仪联合检查能更客观准确地鉴别血尿来源。 Objective :To evaluate the clinical application value for distinguishing glomerular hematuria from non- glomerular hematuria by phase- contrast microscope and Sysmex UF- 100 automated flow eytometer. Methods: One hundred and eighty - nine urine samples were both detected by Olympus BX51 phase - contrast microscope and UF - 100. The urinary erythrocyte morphology was analyzed using phase contrast microscope was analyzed by three criteria. Results: Abnormal erythrocytes ≥70% and ≥3 kinds, or acanthocytes ≥ 5% were used for the diagnosis of glomerular hematuria, the sensitivity and specificity were 81.1% and 89.1% respectively, indicating that it was significantly better than the other two criteria, The sensitivity of UF - 100 (91.6%) was higher than that of phase - contrast microscope (81.1%), but the specificity of phase- contrast microscope(84.8% ) was higher than that of UF- 100(58.7% ). Conclusion: Combination of phase- contrast microscope and UF- lO0 may be used to diag- nose the source of hematuria more objectively and accurately.
出处 《中国卫生检验杂志》 北大核心 2013年第2期408-410,共3页 Chinese Journal of Health Laboratory Technology
关键词 血尿 相差显微镜BX51 UF-100尿沉渣分析仪 Hematuria Phase- contrast microscope Sysmex UF- 100 automated flow cytometer
  • 相关文献

参考文献6

  • 1Birch DF, Fairley KF. Haematuria: glomerular or non - glomemlar? [J]. Lancet, 1979, 314(8147) :845 -846.
  • 2叶任高,毛晓玲.尿畸形红细胞发生机理探讨[J].中华内科杂志,1994,33(2):77-79. 被引量:13
  • 3Tomita M,Kitamoto Y,Nakayama M, et al. A new morphological clas- sification of urinary erythrocytes for differential diagnosis of glomerular hematuria [ J ]. Clin Nephrol, 1992, 37 (2) : 84 - 89.
  • 4Venkat Raman G, Pead L, Lee HA,et al. A blind controlled trial of phase -contrast microscope by two observers for evaluating the source of haematuria [ J ]. Nephron, 1986, 44 (4) :304 - 308.
  • 5熊立凡,顾晓菁,董晓蓓.尿棘形红细胞在肾性和非肾性血尿鉴别中的意义[J].上海医学检验杂志,2000,15(2):74-76. 被引量:25
  • 6Kohler H, Wandel E, Bmnck B, Acanthocyturia- a characteristic maker for glomerular bleeding [ J ]. Kidney lnt, 1991 , 40 ( 1 ) : 115 - 120.

二级参考文献1

  • 1Saod,TF.Dysmorphic urinary erythrocytes[].The New England Journal of Medicine.1996

共引文献36

同被引文献37

引证文献4

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部