摘要 提出了一种零电流开关结构的单开关管的三相升压功率因数校正整流器 .软开关动作可用低功率的辅助电路来实现 .文中分析了ZCT电路的工作原理 ,给出了电路设计的准则 ,并对一个1kW、50kHz的整流器进行了仿真 .结果显示总谐波失真小于 9% . Zero current transition (ZCT) topology of the single switch three phase boost power factor correction (PFC) rectifier is proposed. The soft transition is achieved with low power auxiliary circuit employing an additional switch. Operation of the ZCT topology is analyzed in detail, design guidelines are provided. The results are verified on 1 kW, 50 kHz, simulated ZCT rectifier with IGBTs. Total harmonic distortion below 9% is obtained.
出处 《北方交通大学学报》 EI CSCD 北大核心 2000年第4期91-97,共7页 Journal of Northern Jiaotong University
关键词 功率因数校正 PFC 零电流跃迁 ZCT 整流器 power factor correction (PFC) zero current transition(ZCT) total harmonic distortion(THD)