期刊文献+

化纤中央空调采用酯化蒸汽余热制热方案的探讨

Discussion on Heating Scheme Using Waste Heat of Esterification Steam in Central Air-Conditioning System of Chemical Fiber
下载PDF
导出
摘要 随着化纤DTY品种结构的调整及产品质量要求的提高,原有的加弹车间空调系统已不能满足产品质量的要求,主要表现在中央空调冬季无制热功能,车间温湿度过低,影响DTY质量及加弹机的生产效率。本文提出了利用聚酯酯化蒸汽余热加热热水作为加弹车间中央环境空调制热的热源,通过余热再利用,不但解决了加弹车间中央空调冬季制热的问题,而且大大节约了中央空调制热的运行成本。该方案对同行业在节能降耗、余热再利用等方面具有重要的指导意义。 With improvement of the adjustment of variety structure product quality requirements, the workshops can' t meet the requirements of product function in winter, low humidity in workshops. These of chemical fiber DTY and the air conditioning system in original quality, mainly including no heating affect the DTY quality and production efficiency of the elasticizer. The thesis describes a way to heat water using waste heat of esterification steam as the heat source of central air-conditioning system in texturing workshops. By recycling the waste heat, it not only solves the heating problem in winter, but also saves operation cost for air-conditioning system greatly. This scheme also has important guiding significance in saving energy, reducing consumption and reusing waste heat in the same industry.
作者 周守伍
出处 《现代纺织技术》 2013年第2期44-46,共3页 Advanced Textile Technology
关键词 中央空调系统 酯化蒸汽 余热再利用 加弹机 central air-conditioning system esterification steam waste heat recycling elasticizer
  • 相关文献

参考文献2

二级参考文献2

  • 1陈沛霖 岳孝方.空调与制冷技术手册[M].上海:同济大学出版社,1991.3-92.
  • 2范祖光.现代机械设备手册[M].北京:机械工业出版社,1996.12-22.

共引文献4