期刊文献+

多层螺旋CT自动管电流调制技术及应用进展 被引量:19

Automatic Tube Current Modulation Techniques in Multi-slice CT Scanning and the Application Progress
下载PDF
导出
摘要 随着计算机X线断层扫描(CT)技术的普及,CT扫描的高辐射剂量日益得到广泛关注。CT低剂量研究也成为了CT研究的热点领域。目前,降低CT扫描剂量的方法众多,而自动管电流调制技术(ATCM)作为一项通过实时曝光控制优化辐射剂量兼顾图像质量的先进技术已在临床工作中应用。不同的设备各有其技术基本原理及指标。对ATCM技术在头颈、胸、腹、盆腔部位应用及其影响因素和局限性等尚需更多的临床研究和改进。 With the popularization of CT scanning technology ,high radiation dose has drawn wide atten- tion, and low-dose CT has become the hot field. Nowdays, many methods could be used to reduce CT radiation dose. Automatic tube current modulation (ATCM) technique, an advanced technology, has been applied in the clinical which optimizes radiation dose through real-time exposure control with the guaranty for image quality. Different equipments have different working principles and indicators, and the application of ATCM technique in head and neck, thorax, abdomen, pelvic cavity and the influencers and limitations still need fur- ther clinical research and improvement.
作者 王倩 赵心明
出处 《医学综述》 2013年第4期702-706,共5页 Medical Recapitulate
关键词 CT扫描 自动管电流技术 低剂量 CT scan Automatic tube current modulation Low-dose
  • 相关文献

参考文献8

二级参考文献81

  • 1魏宝杰,张镭,翟仁友,王亚杰.低剂量双螺旋CT薄层扫描筛查早期肺癌初步研究[J].中国医学影像技术,2003,19(11):1519-1522. 被引量:27
  • 2李真林,杨志刚,郭应坤,余建群,李媛,陈宪,谈伟.管电流调制技术在多层螺旋CT胸部检查中的应用评价[J].中国医学影像技术,2006,22(6):858-860. 被引量:7
  • 3王远萍,林大全,付涛.组织等效材料的组成结构对辐射等效性影响的研究[J].生物医学工程学杂志,1997,14(1):42-49. 被引量:2
  • 4Kalra MK, Maher MM, Toth TL, et al. Strategies for CT radiation dose optimization. Radiology, 2004,230(3):619-628.
  • 5Kalra MK, Maher MM, Toth TL, et al. Teehniques and applications of automatic tube current modulation for CT. Radiology, 2004,233(3) : 649-657.
  • 6Johnson PT, Fishman EK. IV contrast selection for MDCT: current thoughts and practice. Am J Roentgenol, 2006, 186(2) :406- 415.
  • 7Kalra MK, Maher MM, Toth TL, et al. Comparison of Z-axis automatic tube current modulation technique with fixed tube current CT scanning of abdomen and pelvis. Radiology, 2004,232(2) :347- 353.
  • 8Kalra MK, Rizzo S, Maher MM, et al. Chest CT performed with z-axis modulation: scanning protocol and radiation dose. Radiology, 2005,237(1) :303-308.
  • 9Rizzo S, Kalra M, Schmidt B, et al. Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis. Am J Roentgenol, 2006,186(3):673 679.
  • 10Payne JT. CT radiation dose and image quality. Radiol Clin North Am, 2005,43(6) :953-962.

共引文献147

同被引文献155

引证文献19

二级引证文献121

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部