期刊文献+

泉州综合交通枢纽站通风空调及节能设计

Quanzhou Comprehensive Transportation Hub HVAC and Energy Saving Design
下载PDF
导出
摘要 根据泉州综合交通枢纽站不同功能区域的特殊要求,有针对性地采用不同形式的空调系统,在候车厅、进出站大厅采用全空气一次回风系统;售票厅、值班室、监控室及快餐厅等采用风机盘管加自然新风系统;贵宾候车室、调度室、站长室及广播(PAS)兼监控室采用风机盘管加新风系统;消防控制室需要24h值班,设置VRV空调系统。冷源采用了螺杆和离心式冷水机组相结合的方式,候车大厅的空调机组采用吊顶式安装。本工程的通风空调及其节能设计,有效地满足了综合交通枢纽站特有的使用功能要求,并能够使其实现节能和可持续发展。 Based on different function's special requirements of Quanzhou transportation hub, different kinds of air-conditioning system should be adopted respectively, for instant, all air system,with primary return air, used for waiting room and station hall; fan-coil fan used for ticket hall, duty room, monitor room and fast-food restaurant; VIP waiting room, dispatching room, station master room and PAS (Public Address System)&monitor room; VRV system used for fire-fighting monitor room, which works 24 hours a day. The screw type and centrifugal water chiller are adopted, air-conditioner hoisted. The HAVC and its energy saving design of this project, could meet the special requirement of function, and also, implement the energy saving and sustainable development.
作者 封宗兴
出处 《工程建设与设计》 2013年第3期110-114,共5页 Construction & Design for Engineering
关键词 综合交通枢纽 通风空调 节能设计 comprehensive transportation hub HVAC energy saving
  • 相关文献

二级参考文献4

  • 1GB50019-2003.采暖通风与空气调节设计规范.[S].,..
  • 2赵荣义,主编.简明空调设计手册.北京:中国建筑工业出版社,1998
  • 3陆耀庆,主编.暖通空调设计指南.北京:中国建筑工业出版社,1996
  • 4孙一坚.空调水系统变流量节能控制[J].暖通空调,2001,31(6):5-7. 被引量:132