摘要 目的探讨早期乳癌的数字化钼钨双靶摄影典型及不典型影像征象。方法对72例早期乳癌病人的全数字化钼钨双靶乳腺摄影影像进行回顾分析。结果 72例中,表现为恶性钙化征象者30例,微小结节者12例,微结节伴钙化8例,不对称性片状致密影15例,结构紊乱7例。结论全数字化钼钨双靶乳腺摄影对早期乳癌的诊断具有很大的帮助。 Objective To investigate typical and atypical imaging signs of early breast cancer on full digital molybdenum dual target breast imaging. Methods The data of imaging of 72 eases with early breast cancer were retrospectively analyzed. Results Of the 72 cases reviewed, 30 showed malignant calcification signs, 12 showed tiny nodules, eight showed tiny nodules with calcification, 15 showed asymmetry flake opacities, and seven showed structural disorder. Conclusion This kind of digital mammography is of great value in the diagnosis of early breast cancer.
机构地区 包钢医院放射科
出处 《齐鲁医学杂志》 2013年第1期37-38,共2页 Medical Journal of Qilu
关键词 乳腺肿瘤 乳房X线摄影术 诊断 breast neoplasms mammography diagnosis
  • 相关文献

参考文献7

二级参考文献34

  • 1周祝谦,梁兴山,王子斌.乳腺未触及肿块的良恶性微小钙化临床X线——病理对照研究[J].实用放射学杂志,1993,9(6):341-345. 被引量:8
  • 2杜勇.乳腺癌的影象学检测[J].国外医学(临床放射学分册),1994,17(3):130-134. 被引量:43
  • 3刘万花,郑凯尔,金爱萍,张元宁,何杰,姚青.全数字化乳腺摄影对妇女致密型乳腺病变的诊断价值[J].中华放射学杂志,2006,40(4):350-353. 被引量:21
  • 4Jiang Y. Malignantand benign clustered microcalcifications[J]. Radiology, 1996,1982,671.
  • 5TinnemansJG, WobbesT, LubbersEJ, et al. The significance of mi-crocalcifications without palpa blemassin the diagnosis of breast cancer[J]. Surgery, 1986,99(6) : 652.
  • 6Winehester DP, Jeske JM, Goldsehmidt RA. The diagnosis and managemen to fduetul eareino main-situ of the breast [J]. CA Caneer J Clin, 2000,50 (3) : 184.
  • 7Feig SA. Ductalcarcino mainsitu implications for sereening mam-mography[J]. Radiol Clin North Am, 2000,38(4) : 653.
  • 8LeGal M, Chavance G, Pellier D. Valeurdiagnostique des micro 2calcification groupees deecuvertes parmammographies (a propos 227 case avesverification histologique etsanstumeur du sein palpable [J]. Bull Cancer. 1984,71 : 571.
  • 9[1]Obenauer S,Hermann KP,Sehom C,et al.Full-field digital mammography:dose-dependent detectability of breast lesions and microealeinosis.Rofo(Gennan),2000,172(12):1052-1056
  • 10[2]Lewin JM,Hendfiek RE,D'Orsi CJ,et al.Comparison of fullfield digital mammography with screen-film mammography for cancer detection:results of 4945 paired examinations.Radiology,2001,218(3):873-880

共引文献20

同被引文献22

  • 1王旭东,王永胜.血浆VEGF CA153 CA125检测对乳腺癌的诊断价值[J].河北医学,2007,13(3):258-261. 被引量:3
  • 2沈镇宙.乳腺癌[M].上海:上海科学技术出版社,1991:102-104.
  • 3SAKORAFAS G H, TSIOTOU A G. Ductal carcinoma in situ (DCIS) of the breast: evolving perspectives[J]. Cancer Treat Rev, 2000,26(2) 103-125.
  • 4BURSTEIN H J, POLYAK K, WONG J S, et al. Ductal car- cinoma in situ of the breastJ. N Engl J Med, 2004, 350= 1430-1441.
  • 5ERNSTER V L, BARCLAY J, KERLIKOWSKE K, et al. Incidence of and treatment for ductal carcinoma in situ of the breast[J]. JAMA, 1996,275:913.
  • 6OKAZAKI A. Progress of ductoscopy of the breast[J]. Nippon Geka Gakkai Zasshi, 1996,97 : 357-362.
  • 7ZHANG B N, ZHANG B, TANG Z H, et al. The development and change of Chinese breast cancer operation treatment of 10 years [J]. Zhonghua Zhong Liu Za Zhi, 2012,34(8):582 587.
  • 8赵晶,刘红,张爱敏,顾林.乳腺癌患者血清可溶性肿瘤标志物的临床价值研究[J].中国肿瘤临床,2008,35(24):1411-1414. 被引量:8
  • 9张祖兰,边林莉.乳头溢液95例临床分析[J].齐鲁医学杂志,2009,24(3):273-274. 被引量:1
  • 10万亚涛,张洪波,杨海波,陈兰英.几种重要肿瘤标志物的发展应用[J].医学理论与实践,2009,22(9):1055-1056. 被引量:13