期刊文献+

改进的Scheibel萃取塔中分散相的停留时间分布模型

An RTD model of dispersed phase in a modified Scheibel extraction column
下载PDF
导出
摘要 通过实验研究了改进的Scheibel萃取塔中分散相的停留时间分布,考察了操作条件、物性参数对分散相停留时间分布的影响.使用脉冲示踪法测量分散相的停留时间分布曲线,使用多釜串联模型处理数据,并通过因次分析法建立了一个计算模型参数为n的关联式.计算值与实验值的最大相对偏差为-14%,平均相对偏差为±5.9%.通过该式计算n,可以得到给定条件下分散相的停留时间分布,有助于进一步研究两相的传质行为. Experiments were designed to study the influence of operation conditions and system physical properties on the residence time distribution (RTD) of the dispersed phase in the modified Scheibel extraction column. RTD of the dispersed phase was measured with the pulse tracer method. The model parameter n of the perfect mixing tanks-in- series model was obtained and a correlation was proposed. The maximum relative error for all data is --14% and the mean relative error is±5.9% The correlation can be used to study the RTD of the dispersed phase in the modified Scheibel extraction column.
出处 《浙江大学学报(理学版)》 CAS CSCD 2013年第2期191-195,共5页 Journal of Zhejiang University(Science Edition)
基金 中央高校基本科研业务费专项资金资助项目(No.2012QNA4017) 浙江省重点科技创新团队计划资助项目(2011R5007)
关键词 改进的Scheibel萃取塔 停留时间分布 多釜串联模型 modified Seheibel extraction column~ residence time distribution perfect mixing tanks-in-series model
  • 相关文献

参考文献8

二级参考文献17

  • 1卢立柱,赵兵,林平.一种水分散型多隔层混合室混合澄清萃取器的设计及操作性能[J].化工学报,1993,44(6):692-699. 被引量:2
  • 2T. C. Lo, M. H. I. Baird, C .Hanson. Handbook of Solvent Extraction [M]. Wiley- Interscience, New York, 1983: 475-485.
  • 3Scheibel E G. Performance of an Internally Baffled Multistage Extraction column[J]. AIChE. 1956,(2): 74-78.
  • 4Scheibel E G. Liquid-liquid extraction column having rotatable pumping impeller assemblies: US, 3389970 [P].1968- 06-25.
  • 5Bonnet J C, Jeffreys G V. Hydrodynamics and mass t ransfer characteristics of a scheibel extractor [J]. AIChE,1985,31: 795-801.
  • 6朱慎林.筛板萃取柱,溶剂萃取手册[M].北京,化学工业出版社.2001:226-225.
  • 7费维扬,工业萃取设备,溶剂萃取手册[M].北京,化学工业出版社.2001:180-188.
  • 8Bonnet J C. Hydrodynamics and mass transfer in a s cheibel extractor [M]. So. Thesis, Aston University, Birmingham, UK, 1982.
  • 9Ettouney R S, E1-Rifai M A, Ghallab A O. Steady state modeling of perforated plate extraction columns [J].Chem Eng Process, 2007,46: 713-720.
  • 10Katsuroku Takahashi.Stage efficiency of mixer-settler extraction column[J].J Chem Eng Japan, 1993, 26(6):715~719.