摘要 神华神东电力有限责任公司萨拉齐电厂1号汽轮机组1号、2号轴承出现了轴振动增大的现象,通过进行现场试验和分析,认为故障是因机组高中压转子存在质量不平衡引起的。在高中压转子中部加装了质量为1653.8 g、相位为205°的平衡块,在中压缸排汽口侧转子上加装了质量为1300 g、相位200°的平衡块后,机组1号、2号瓦轴振动值均降至70μm以内。 No.1 and No.2 bearings' shaft vibration increased on Unit 1 in Shenhua Shendong Power Co.,Ltd. Salaqi Power Plant. Through field test and analysis, the author thought the failure was due to the unit's high-medium pressure rotor quality imbalance. After fixed balance block in the high-middle pressure rotor with mass of 1653.8 g and the phase of 205°,balance block in the rotor of medium pressure cylinder on exhaust port side with the mass of 1300 g and the phase of 200°, No.1 and No.2 bearings' vibration values were decreased to 70 μm in Unit 1.
作者 杨柏
出处 《内蒙古电力技术》 2013年第1期50-54,共5页 Inner Mongolia Electric Power
关键词 汽轮机 轴振动 动平衡 临界转速 热弯曲 应力 steam turbine axial vibration dynamic balance critical speed thermalbending stress
  • 相关文献

参考文献5

  • 1上海汽轮机厂有限公司.A153汽轮机说明书[M].上海:上海汽轮机厂有限公司,2010:5-16.
  • 2内蒙古电力科学研究院.神华神东电力萨拉齐电厂#1机组启动振动监测报告[R].呼和浩特:内蒙古电力科学研究院,2011:2-3.
  • 3北京电联天时振动技术有限公司.神东萨拉齐电厂1号汽轮发电机组高中压转子三平面加重动平衡报告[R].北京:北京电联天时振动技术有限公司,2012:3-5.
  • 4肖高绘,葛庆,蒋浦宁,李道云.600MW超临界机组高中压转子弯曲的动平衡修复[J].热力透平,2009,38(4):259-262. 被引量:9
  • 5袁立平,李力,谭士森.高中压合缸300MW汽轮机弯曲转子动平衡[J].河南电力,2001,29(1):6-7. 被引量:2