摘要 对内蒙古京隆发电有限责任公司600 MW机组锅炉运行中存在的磨煤机出力不足、暖风器差压大、暖风器结垢严重等问题进行了分析,提出将固定暖风器更换为旋转暖风器的改造方案,介绍了旋转暖风器的可旋性、低阻力、堵灰不泄漏等特点。改造为旋转暖风器后,压降及电流明显减小,有效防止了一次风机失速及夏季一、二次风机电机绕组温度高等问题;同时减小了一次、二次风机的耗电量,降低了运行成本。改造后,再未发生一次风机失速故障,年节约费用约86.621万元。 This article studies the cases of the fixed heater units of Inner Mongolia Jing Long Electric Power Generation Co.,Ltd. The operation of its 600 MW boiler has the shortcomings of coal mill output deficiency, heater unit pressure difference and heater device scaling problem. Rotating heater appliances are more optional with no leaking and lower resistance. By transforming the fixed heater unit into the rotating heater unit, voltage and current had been decreased significantly. Meantime, the primary fan stall and high machine winding temperature of the primary and secondary fan were effectively prevented. The rotating heater unit has not only reduced the power consumption of primary and secondary fan, but also saved cost for the cooperation. After reconstrustion, there was no a single fan stall problem in 2012 in Jing Long Power Plant, and a total of 86 6210 Yuan has been saved.
出处 《内蒙古电力技术》 2013年第1期69-72,共4页 Inner Mongolia Electric Power
关键词 暖风器 旋转改造 失速 节能改造 air heater rotation transformation stall energy efficiency reconstruction
  • 相关文献

参考文献4

  • 1内蒙古京隆发电有限责任公司.内蒙古京隆发电有限责任公司企业标准集控运行规程[S].丰镇:内蒙古京隆发电有限责任公司,2010:20-33.
  • 2内蒙古京隆发电有限责任公司.内蒙古京隆发电有限责任公司企业标准辅机运行规程[S].丰镇:内蒙古京隆发电有限责任公司,2010:36-37,166-168.
  • 3袁镇福,田子平.电站锅炉原理[M].北京:中国电力出版社2002:85-110.
  • 4中国动力工程学会.火力发电技术手册(第一卷锅炉)[M].北京:机械出版社,2002:56-88.

共引文献4

同被引文献6

引证文献4

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部