300MW煤矸石发电机组SO_2排放超标原因分析及处理措施 被引量:4

Cause Analysis and Its Treatment for SO_2 Emission Exceeding in 300 MW Coal Gangue Generating Units
下载PDF
导出
摘要 神华神东电力有限责任公司萨拉齐电厂2×300 MW煤矸石发电机组在投产初期,高负荷时SO2排放指标超标,分析认为主要原因为设计煤种与实际燃用煤种发热量及硫分差异较大、锅炉床温高及石灰石系统投入率低等。对此,提出加大矸石与低硫煤的掺烧质量比至7∶3,对锅炉进行一、二次风量及上、下二次风量送入比例进行优化调整,合理分布石灰石粒径、保证石灰石系统投入等解决措施。实施后效果良好,SO2排放超标问题得到解决。 SO2 exceeded emission standard at high load when Salaqi Power Plant put into service in the early stage, because of the calorific value and sulfur content larger between the designed and actual burning coal, the circulating fluidized boiler's high bed temperature and the limestone system's low run rate. By taking measures that increasing the proportion of waste rock and low-sulfur coal to 7:3, adjusting the boiler running operation between the primary air and secondary air, distributing reasonably limestone powder diameter and ensuring the run rate of limestone system etc, the level of SO2 emission has been obviously decreased and meets the current requirements of environmental protection emission standard in the end.
作者 段守保
出处 《内蒙古电力技术》 2013年第1期109-112,共4页 Inner Mongolia Electric Power
关键词 循环流化床锅炉 烟气污染物 SO2排放超标 床温 硫分 circulating fluidized bed (CFB) boiler flue gas pollutants S02 exceedingemission standard bed temperature sulfur content
  • 相关文献

参考文献5

  • 1哈尔滨锅炉厂有限责任公司.HG-1065/17.5-L.MG44锅炉机组说明书F0310GL00lL041[M].哈尔滨:哈尔滨锅炉厂有限责任公司,2009:6-7.
  • 2中国环境科学研究院.神华神东电力土右2×300MW(CFB)煤矸石发电工程环境影响报告书[R].北京:中国环境科学研究院,2008:143.
  • 3西北电力设计院.神华神东电力萨拉齐发电厂工程初步设计阶段(第1卷)[M].西安:西北电力设计院,2008:73-74.
  • 4国家环境保护总局,国家质量监督检验检疫总局.GB13223-2003火电厂大气污染物排放标准[S].北京:中国环境科学出版社,2003.
  • 5中国环境监测总站.神华神东电力土右2×300MW(CFB)煤矸石发电工程竣工环境保护验收监测报告[R].北京:中国环境监测总站,2012:38.

共引文献3

同被引文献28

  • 1吕清刚,雍玉梅,那永洁,包绍麟,孙运凯,贺军,矫维红,高鸣.循环流化床燃煤锅炉的SO_2和NO_x排放的试验和数值计算[J].中国电机工程学报,2005,25(1):142-146. 被引量:43
  • 2李雄,刘军,岳光溪,陈伟刚,钱朝龙,吕俊复.循环流化床锅炉深度脱硫与超低排放[J].锅炉技术,2007,38(6):26-31. 被引量:19
  • 3国家能源局.关于促进低热值煤发电产业健康发展的通知(国能电力[2011]396号)[EB/OL].http:/!www.nea.gov.cn/2011-12/30/c-131335980.htm.2011-12-30.
  • 4陈春元,聂立,肖峰,等.循环流化床锅炉燃烧设备性能设计方法[M].哈尔滨:普华煤燃烧技术研发中心,2007.
  • 5HJBAT-001,燃煤电厂污染防治最佳可行技术指南(试行)[s].
  • 6Stephen J, Goidich. Circulating fluidized bed technology utility - scale unit experiences. Foster Wheeler Energy Corporation.
  • 7Makansi, Jason. CFBs anchor premier approach to extracting value from solid fuels. Power, Mar 1, 2005.
  • 8吉林省电力科学研究院有限公司.华能白山煤矸石发电厂2号机组脱硫设施评估报告[R].长春:吉林省电力科学研究院有限公司,2013.
  • 9科技部,环境保护部.大气污染防治先进技术汇编[EB/OL].http://www, zhb. gov. cn/zhxx/hjyw/201403/t20140312_269081. htm,2014 -03 -26.
  • 10哈尔滨锅炉厂有限责任公司.HG-1065/17.5-LMG44锅炉机组说明书(F0310GL001L041)[M].哈尔滨:哈尔滨锅炉厂有限责任公司,2009:6-7.

引证文献4

二级引证文献36

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部