在综述文献和谱线表数据的基础上,实验研究了ICP-AES法测定钢铁中硅的分析线。基体匹配得标样经校正后,Si212.412 nm和Si251.612 nm分析线测定钢铁中硅的检出限达0.0006%,比现行国家标准方法改善约两个数量级。
Based on reviewing references and wavelength tables, experimental investigation of Si lines for the determination of Si in steel is reported. Calibration was made under conditions of matrix match and blank correction. Limit of detection is 6 x 10^(-4) % for Si 212.412 um and Si 251. 612 um and is two orders of magnitude betten than the current national standard methods.
出处
《分析化学》
SCIE
EI
CAS
CSCD
北大核心
2000年第8期971-973,共3页
Chinese Journal of Analytical Chemistry
关键词
硅
钢铁
微量分析
ICP-AES