摘要
介绍了基于Windows平台的心阻抗血流图 (ICG)检测系统的设计过程 ,并对 30名学员进行了该系统的初步临床ICG检测 ,测算的ICG三项主要指标与文献中的检测结果的对比研究表明 ,两者不仅检测结果符合率较好 ,而且与DOS环境下设计的系统相比 ,本系统检测速度大大提高 ,鼠标的引入使操作更简便。
In this paper is introduced systematically the design of the system for detecting impedance cardiography(ICG)based on Windows plantform.The three major ICG indexes of 30 students have been detected by the designed system in the clinical application,and conform with the results from the reference.On the other hand,compared with the system based on DOS plantform,the system has higher detection speed,and becomes more convenient,more flexible by the introduction of Mouse.
出处
《中国医疗器械杂志》
CAS
2000年第5期263-266,共4页
Chinese Journal of Medical Instrumentation