摘要 总结326例肿瘤患者在中心静脉置管过程中应用心电导联技术的护理经验。通过穿刺过程中加强护患沟通,利用心电图P波改变及时调整导管尖端位置,改变穿刺方法,提高了穿刺成功率,减少了X线的放射性污染及穿刺点的局部出血。本组326例患者均成功置管,1次置管成功率相比传统中心静脉置管提高了约4%。本组6例患者在未见P波改变情况下,改用X线定位;78例患者穿刺处少量渗血持续2~3 d,经积极处理后,出血停止。所有病例均顺利完成化疗。 This paper introduced the application of electrocardiogram in central venous catheterization for 326 patients with tumors and its nursing care. With the change of P wave of electrocardiography, the central venous catheter tip could be inspected, which contributed to the improvement of success rate and there was less radioactive pollution from X-ray and less local hemorrhage in puncture point. All catheters were successfully placed and the success rate was improved. Since no change of P wave was detected, the central venous catheter was placed with X-ray positioning among six patients. Oozing lasted in puncture point among 78 patients for 2 to 3 days and stopped after treatment. The communication between patients and nurses played a critical part in the whole process. Successful completion of chemotherapy was witnessed in all patients in the study.
机构地区 浙江省肿瘤医院
出处 《护理学报》 2013年第6期51-52,共2页 Journal of Nursing(China)
关键词 中心静脉置管 心电图定位 X线定位 肿瘤患者 静脉治疗 central venous catheterization positioning with electrocardiogram positioning with X-ray patient with tumor intravenous therapy
  • 相关文献

参考文献5

二级参考文献57

  • 1许晓云.PICC导管异位的原因分析及预防[J].中国实用神经疾病杂志,2007,10(8):124-125. 被引量:67
  • 2楼晓芳,高剑虹,朱海虹.新生儿PICC导管异位的原因分析及预防[J].中华护理杂志,2004,39(8):621-622. 被引量:68
  • 3陈向荣,王晓娅,李丽,倪柳琴.经外周中心静脉导管异位14例的原因分析及预防[J].解放军护理杂志,2005,22(7):68-69. 被引量:80
  • 4陈雅玫,石新华.肿瘤患者PICC置管后并发静脉血栓的护理[J].护理学报,2007,14(2):65-66. 被引量:58
  • 5Ralf EG, Peter S, Evan GP, et al. The accuracy electrocardiogram-controlled central of line placement [ J ]. Anes & Anal, 2007, 104 : 65 - 70.
  • 6Peres PW. Positioning central venous catheters-a prospective survey[J]. Anaesth Intens Care, 1990,18:536.
  • 7McGee DC, Gould MK. Preventing complications of central venous catheterization[ J ]. N Engl J Med, 2003, 348 : 1123 - 1133.
  • 8Darling JC, Newel1 SJ, Mohamdee O, et al. Central venous catheter tip in the right atrium: a risk factor for neonatal cardiac tamponade[J]. J Perinatlol, 2001, 21 (7):461 - 464.
  • 9Schummer W, Schummer C, Schelenz C, et al. Modified ECG-guidance for optimal central venous catheter tip positioning. A transesophageal echocardiography controlled study[ J]. Anaesthesist, 2005, 54:983 - 990.
  • 10Domino KB, Bowdle TA, Posner KL, et al. Injuries and liability related to central vascular catheters: a closed claims analysis[ J]. Anesthesiology, 2004, 100 : 1411 - 1418.

共引文献157

同被引文献34

  • 1Pittiruti M, La Greca A, Scoppettuolo G. The electrocardiographic method for positioning the tip of central venous catheters [ J ]. J Vasc Access, 2011,12 (4) : 280-291. DOI: 10. 5301/JVA. 2011. 8381.
  • 2Petersen J, Delaney JH, Brakstad MT, et al. Silicone venous access devices positioned with their tips high in the superior vena cava are more likely to malfunction[J]. Am J Surg, 1999,178 (1): 38-41.
  • 3Caers J, Fontaine C, Vinh-Hung V, et al. Catheter tip position as a risk factor for thrombosis associated with the use of subcutaneous infusion ports [ J]. Support Care Cancer, 2005,13 (5) : 325-331.
  • 4McGee DC, Gould MK. Preventing complications of central venous catheterization [ J ]. N Engl J Med, 2003,348 ( 12 ) : 1123-1133.
  • 5Parienti J J, Mongardon N, Megarbane B, et al. Intravascular Complications of Central Venous Catheterization by Insertion Site [J]. N Engl J Med,2015,373 (13) : 1220-1229. DOI: 10. 1056/NEJMoa1500964.
  • 6Infusion Nurses Society. Infusion Nursing Standards of Practice [ J ]. J Infus Nurs,2006,29 ( 1 Suppl) : S1 -S92.
  • 7Hughes RE, Magovern GJ. The relationship between right atrial pressure and blood volume [ J ]. AMA Arch Surg, 1959,79 ( 2 ) : 238 -243.
  • 8Smith B, Neuharth RM, Hendfix MA, et al. Intravenous electrocardiographic guidance for placement of peripherally inserted central catheters [ J]. J Eleetroeardiol, 2010,43 ( 3 ) : 274-278. DOI : 10. 1016/j. jeleetroeard. 2010.02. 003.
  • 9Pittiruti M, Bertollo D, Briglia E, et al. The intracavitary ECG method for positioning the tip of central venous catheters: results of an Italian multieenter study [ J ]. J Vase Access,2012, 13 (3) : 357-365. DOI: 10. 5301/JVA. 2012. 9020.
  • 10Kremser J, Kleemann F, Reinhart K, et al. Optimized method for correct left-sided central venous catheter placement under electrocardiographic guidance [ J ]. Br J Anaesth, 2011,107 ( 4 ) : 567-572. DOI: 10. 1093/bja/aer189. Epub 2011 Jun 22.

引证文献2