摘要
以爆炸性环境相关标准规定作为Ma级本质安全型矿灯设计的理论基础,分析了现行矿灯存在的差距,确立了Ma级矿灯电源的三级保护方案和对系统保护参数进行了优化设计,同时对罕见的电源故障也采取了应对措施。它将使我国矿灯的防爆类型由特殊型(ExsI Mb)提升到本质安全型(ExiaI Ma)。
This paper uses the relevant standards and regulations of explosive atmosphere as the theoretical basis for the design of Ma - level intrinsically safe minerg lamp, analyzes the difference between Ma - level and the present commonly - used minerg lamps, estab- lishes the three - level protective scheme of Ma - level minerg lamp power, optimizes and designs the protective parameters of the sys- tem. Meanwhile, the paper takes measures on the rare power failures. This improves explosion- proof type of the minerg lamp in our country from special type (ExsI Mb) to intrinsically safe type (Exial Ma).
出处
《煤矿安全》
CAS
北大核心
2013年第3期132-135,共4页
Safety in Coal Mines
基金
辽宁省产业技术研究与开发专项资金资助项目(2069999)
关键词
Ma级
本质安全
矿灯
Ma level
intrinsic safety
minerg lamp