摘要 目的防止不可控的放射性物质传入我国,保护我国环境及人民身体健康。方法对2012年1月进口的硝酸钾货物进行放射性检测。结果监测点的平均剂量率水平(本底值)为0.13~0.18μSv/h,测得货物整体最高值为0.75μSv/h;β/γ活度最高值为1.95Bq/cm2。结论对放射性异常的判定,需经科学合理的分析,并结合实验室检测作出定论。 Objective This paper aims to prevent uncontrollable radioactive substances from entering our country, and protect our environment and the health of the residents. Methods Radiation detections are carried out on potassium nitrate cargos imported in January, 2012. Results The background level at the monitoring port is 0.13 0. 18 μSv / h. The maximum value of the measured integrated cargos is 0. 75p, Sv / h. The active peak value of β/ γ is 1.95 Bq / cm2. Conclusion The conclusion of abnormal radiation should be subject to scientific and rational analysis, combined with laboratory testing.
出处 《口岸卫生控制》 2013年第1期31-32,共2页 Port Health Control
关键词 放射性 检测 调查 Radiation protect investigation
  • 相关文献

参考文献6

  • 1关于印发《口岸核生化有害因子监测技术方案》的通知(国质检卫[2010]424号).
  • 2《进口矿产品放射性检验规程》(SN/T1537-2005).
  • 3《放射性物质安全运输规程》(GBl1806-2004).
  • 4《用半导体γ谱仪分析低比活度γ放射性样品的标准方法》(GB11713-1989).
  • 5《电离辐射防护与辐射源安全基本标准》(GB18871-2002).
  • 6口岸核辐射检测技术手册陆永贵著.