摘要
目前使用的排水器普遍存在着一室容积太小,易造成排水器冷凝水管堵塞,清理难度大问题。针对这一缺陷,在现运行的煤气排水器结构不变的基础上进行自主改装,增加"储灰室",来增加煤气排水器一室的容积,有效防止排水器堵塞。
The volume of currently used drainer is too small, easily resulting in block- age of drainer's condensing water pipe and difficult to clean. For this reason, the drainer was independently reconstructed under the condition that structure of the existing gas drainer was unchanged, and an ash storing chamber was added to increase volume of the gas drainer. It effectively prevented the drainer from blocking up.
出处
《冶金动力》
2013年第3期19-20,共2页
Metallurgical Power
关键词
排水器
储灰室
冷凝水管
堵塞
drainer
ash storing chamber
condensing water pipe
blockage